MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Examining the safety and efficacy of a chemotherapy dosing method in Allogeneic Stem Cell Transplant patients of extreme body size
Examining the safety and efficacy of a chemotherapy dosing method in Allogeneic Stem Cell Transplant patients of extreme body size
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Examining the safety and efficacy of a chemotherapy dosing method in Allogeneic Stem Cell Transplant patients of extreme body size
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Examining the safety and efficacy of a chemotherapy dosing method in Allogeneic Stem Cell Transplant patients of extreme body size
Examining the safety and efficacy of a chemotherapy dosing method in Allogeneic Stem Cell Transplant patients of extreme body size

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Examining the safety and efficacy of a chemotherapy dosing method in Allogeneic Stem Cell Transplant patients of extreme body size
Examining the safety and efficacy of a chemotherapy dosing method in Allogeneic Stem Cell Transplant patients of extreme body size
Journal Article

Examining the safety and efficacy of a chemotherapy dosing method in Allogeneic Stem Cell Transplant patients of extreme body size

2009
Request Book From Autostore and Choose the Collection Method
Overview
Background. There is no consensus on a universal dosing method for calculating high-dose chemotherapy in allogeneic Stem Cell Transplant (SCT) patients. The Metropolitan Life (Met-Life) Insurance Company’s weight—height tables have been used to determine body weight for chemotherapy dosing for SCT, however no formal study has been done to determine if the Met-Life weight— height tables can be used for chemotherapy dosing in SCT. We retrospectively studied the use of Met-Life weight—height tables for chemotherapy dosing in SCT. Our goal is to determine if patients with extremes of body size who had undergone an SCT and were dosed according to the Met-Life weight— height tables had an increase of Treatment Related Morbidity (TRM) or mortality or relapse. Patients and Methods. Patients were grouped into three different treatment regimens, cyclophosphamide/TBI, busulphan/cyclophosphamide, and AraC/cyclophosphamide/TBI. Patients in each treatment regimen were further divided into five equal groups based on weight. Treatment related morbidity and mortality was evaluated by comparing the lowest and highest quintiles to the middle quintiles within each treatment regimen. Result. Data from 262 patients was evaluated in this study. Overall, there was not an increase in TRM or mortality or in relapse in patients with extremes of body size. Conclusion. The Met-Life weight—height tables could be used to dose patients undergoing allogeneic SCTs. Additional prospective studies would need to be done comparing other chemotherapy dosing methods with the Met-Life weight—height tables to further validate this conclusion.