Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Maximization of injected power and efficiency based optimal location of DPFC using iterative procedure
by
Gupta, Ravi Kumar
, Gupta, Dheeraj Kumar
, Ranjan, Mrinal
, Gupta, Santosh Kumar
, Tripathi, Jayant Mani
in
Capacitors
/ Compensators
/ Controllers
/ Converters
/ distributed power flow controller
/ Efficiency
/ Electric power systems
/ Engineering schools
/ Equivalent circuits
/ facts
/ Iterative methods
/ maximum power transfer capability
/ optimal location
/ Optimization
/ Power
/ Power flow
/ Redundancy
/ Resonant frequencies
/ Systems stability
/ Thyristors
/ Transmission lines
2022
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Maximization of injected power and efficiency based optimal location of DPFC using iterative procedure
by
Gupta, Ravi Kumar
, Gupta, Dheeraj Kumar
, Ranjan, Mrinal
, Gupta, Santosh Kumar
, Tripathi, Jayant Mani
in
Capacitors
/ Compensators
/ Controllers
/ Converters
/ distributed power flow controller
/ Efficiency
/ Electric power systems
/ Engineering schools
/ Equivalent circuits
/ facts
/ Iterative methods
/ maximum power transfer capability
/ optimal location
/ Optimization
/ Power
/ Power flow
/ Redundancy
/ Resonant frequencies
/ Systems stability
/ Thyristors
/ Transmission lines
2022
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Maximization of injected power and efficiency based optimal location of DPFC using iterative procedure
by
Gupta, Ravi Kumar
, Gupta, Dheeraj Kumar
, Ranjan, Mrinal
, Gupta, Santosh Kumar
, Tripathi, Jayant Mani
in
Capacitors
/ Compensators
/ Controllers
/ Converters
/ distributed power flow controller
/ Efficiency
/ Electric power systems
/ Engineering schools
/ Equivalent circuits
/ facts
/ Iterative methods
/ maximum power transfer capability
/ optimal location
/ Optimization
/ Power
/ Power flow
/ Redundancy
/ Resonant frequencies
/ Systems stability
/ Thyristors
/ Transmission lines
2022
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Maximization of injected power and efficiency based optimal location of DPFC using iterative procedure
Journal Article
Maximization of injected power and efficiency based optimal location of DPFC using iterative procedure
2022
Request Book From Autostore
and Choose the Collection Method
Overview
Among the FACTS device, the distributed power flow controller (DPFC) is a superior device. This can be evaluated after eliminating the dc capacitor between shunt and series convertors of the unified power flow controller (UPFC) and placing a number of low rating single phase type distributed series convertors in the line instant of using single large rating three phase series convertors as in the UPFC. The power flow through this dc capacitor as in the UPFC now takes place through the transmission line at a third harmonic frequency in the DPFC. The DPFC uses the D-FACTS that allows the replacement of a large three-phase converter as in the UPFC by several small-size series convertors present in the DPFC. The redundancy of several series convertors increases the system’s reliability of the power system. Also, there is no requirement for high voltage isolation as series convertors of the DPFC are hanging as well as single-phase types. Consequently, the DPFC system has a lower cost than the UPFC system. In this paper, the equivalent ABCD parameters of the latest FACTSdeviceDPFChave been formulated with the help of an equivalent circuit model of the DPFC at the fundamental frequency component. Further, the optimal location in the transmission line and maximum efficiency of the DPFC along with Thyristor Controlled Series Compensator (TCSC), Static Synchronous Shunt Compensator (STATCOM) and UPFC FACTS devices have been investigated using an iteration program developed in MATLAB under steady-state conditions. The results obtained depict that the DPFC when placed slightly off-center at 0.33 fraction distance from the sending end comes up with higher performance. Whereas, when the TCSC, STATCOM and UPFC are placed at 0.16, 0.2815, 0.32 fraction distances from sending end respectively give their best performance.
Publisher
Polish Academy of Sciences
Subject
MBRLCatalogueRelatedBooks
Related Items
Related Items
We currently cannot retrieve any items related to this title. Kindly check back at a later time.
This website uses cookies to ensure you get the best experience on our website.