MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Fabrication of sealed source scandium-46 (46Sc) as an alternative calibration standard
Fabrication of sealed source scandium-46 (46Sc) as an alternative calibration standard
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Fabrication of sealed source scandium-46 (46Sc) as an alternative calibration standard
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Fabrication of sealed source scandium-46 (46Sc) as an alternative calibration standard
Fabrication of sealed source scandium-46 (46Sc) as an alternative calibration standard

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Fabrication of sealed source scandium-46 (46Sc) as an alternative calibration standard
Fabrication of sealed source scandium-46 (46Sc) as an alternative calibration standard
Journal Article

Fabrication of sealed source scandium-46 (46Sc) as an alternative calibration standard

2024
Request Book From Autostore and Choose the Collection Method
Overview
Cobalt-60 is usually used for calibration standard that nowadays, it hard to fabricated. This research aims to fabricate of Sealed Source 46 Sc as alternative Calibration Standard. Sealed source 46 Sc radioactivity was 1.17 ± 0.08 µCi, sealed with an aluminum label. Radiation exposure on the surface opened container is 19.27 ± 0.09 µSv/h, a closed is 10.78 ± 0.15 µSv/h and the distance of 1 m from an open container is 4.40 ± 0.04 µSv/h whereas closed has 2.40 ± 0.04 µSv/h. Multi-channel analyzer γ-spectrometry showed the 46 Sc gamma spectrum similar with characteristics from standard 60 Co source.