Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Design and Development of Intracavity Optical Parametric Oscillator-based Eye Safe Laser Operating at 20 Hz without Forced Air Cooling
by
Bhardwaj, Atul
, Agrawal, Lalita
, Maini, Anil
in
Arrays
/ Coolers
/ Defence
/ Design engineering
/ Gain
/ Laser diodes
/ Lasers
/ Optical oscillators
/ Optical properties
/ Signal processing
/ Thermoelectricity
2013
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Design and Development of Intracavity Optical Parametric Oscillator-based Eye Safe Laser Operating at 20 Hz without Forced Air Cooling
by
Bhardwaj, Atul
, Agrawal, Lalita
, Maini, Anil
in
Arrays
/ Coolers
/ Defence
/ Design engineering
/ Gain
/ Laser diodes
/ Lasers
/ Optical oscillators
/ Optical properties
/ Signal processing
/ Thermoelectricity
2013
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Design and Development of Intracavity Optical Parametric Oscillator-based Eye Safe Laser Operating at 20 Hz without Forced Air Cooling
by
Bhardwaj, Atul
, Agrawal, Lalita
, Maini, Anil
in
Arrays
/ Coolers
/ Defence
/ Design engineering
/ Gain
/ Laser diodes
/ Lasers
/ Optical oscillators
/ Optical properties
/ Signal processing
/ Thermoelectricity
2013
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Design and Development of Intracavity Optical Parametric Oscillator-based Eye Safe Laser Operating at 20 Hz without Forced Air Cooling
Journal Article
Design and Development of Intracavity Optical Parametric Oscillator-based Eye Safe Laser Operating at 20 Hz without Forced Air Cooling
2013
Request Book From Autostore
and Choose the Collection Method
Overview
In this paper we report the design and development of an electro-optically Q-switched diode pumped Nd:YAG laser with intracavity optical parametric oscillator, generating ~ 5 ns laser pulses of ~8 mJ energy at eye safe wavelength of 1534 nm. A Z-shaped laser resonator has been designed with porro prism end reflector in Q-switch arm containing RTP Q-Switch and a suitably oriented waveplate. The gain arm consists of a Oe3 x 72 mm Nd: YAG laser rod, pumped from one side by 3 x 5 bar laser diode array stack emitting total optical peak power of 740 W at 804 nm at 38 degree C. Thermoelectric coolers (TECs) have been employed to maintain the optimum temperature of laser diode arrays and the combined heat load from the pump chamber and TECs is distributed over the system base plate with embedded heat pipes. Such cooling mechanism has eliminated the requirement of fins and fans in the laser system. Eye safe radiation is out-coupled through intra cavity KTA OPO (5 x 5 x 20 mm3) placed in the gain arm. Laser was operated at 20 Hz for several duty cycles of 10 min on and 10 min off and output energy remained stable within plus or minus 0.5 mJ without any forced air/liquid cooling. Defence Science Journal, 2013, 63(6), pp.599-605, DOI:http://dx.doi.org/10.14429/dsj.63.5759
Publisher