Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Lung radiotherapy verification with a 3D printed thorax phantom and an ionisation chamber array
by
Jessen, L.
, Crowe, S.B.
, Kairn, T.
, Charles, P. H.
, Bodnar, J.
in
3-D printers
/ Arrays
/ Dosimetry
/ Error analysis
/ Ionization chambers
/ Lungs
/ Physics
/ Radiation therapy
/ Thorax
/ Three dimensional printing
2023
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Lung radiotherapy verification with a 3D printed thorax phantom and an ionisation chamber array
by
Jessen, L.
, Crowe, S.B.
, Kairn, T.
, Charles, P. H.
, Bodnar, J.
in
3-D printers
/ Arrays
/ Dosimetry
/ Error analysis
/ Ionization chambers
/ Lungs
/ Physics
/ Radiation therapy
/ Thorax
/ Three dimensional printing
2023
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Lung radiotherapy verification with a 3D printed thorax phantom and an ionisation chamber array
by
Jessen, L.
, Crowe, S.B.
, Kairn, T.
, Charles, P. H.
, Bodnar, J.
in
3-D printers
/ Arrays
/ Dosimetry
/ Error analysis
/ Ionization chambers
/ Lungs
/ Physics
/ Radiation therapy
/ Thorax
/ Three dimensional printing
2023
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Lung radiotherapy verification with a 3D printed thorax phantom and an ionisation chamber array
Journal Article
Lung radiotherapy verification with a 3D printed thorax phantom and an ionisation chamber array
2023
Request Book From Autostore
and Choose the Collection Method
Overview
In this study, a 3D printing error inspired the development of a novel method for using a sagittally-sliced 3D printed thorax phantom to perform dosimetric verifications of lung radiotherapy treatment methods using a 2D ionization chamber array. A full-size thorax model was designed for 3D printing with multiple tissue densities including lung and bone and printed as a series of 2.4 cm sagittal slices using a Raise 3D Pro dual nozzle printer (Raise 3D Technologies Inc, Irvine, USA). An error introduced midway through printing resulted in one half of the phantom being printed at unrealistically high densities. A method was therefore devised whereby the entire phantom was used to plan two lung treatments, one conventionally fractionated and one hypo-fractionated, which were then verified via measurements using an Octavius 729 ionisation chamber array (PTW-Freiburg GmbH, Freiburg, Germany) in combination with several correctly-printed slices of the phantom. The measurements allowed dose distributions in planes through the target, adjacent to the target and at the location key of organs at risk to be verified, for both treatment plans. This method has the potential to be adapted for use with other phantoms and other dosimetry arrays to allow efficient evaluation of future treatment techniques.