Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Fast and accurate on-site determination of rotenone in water during fish control treatments using liquid chromatography
by
Sandodden, Roar
, Sandvik, Morten
, Bardal, Helge
, Rundberget, Thomas
, Adolfsen, Pål
, Waaler, Thor Arnulf
in
Acetonitrile
/ Chromatography
/ Liquid chromatography
/ Preservation
/ Rivers
/ Rotenone
2018
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Fast and accurate on-site determination of rotenone in water during fish control treatments using liquid chromatography
by
Sandodden, Roar
, Sandvik, Morten
, Bardal, Helge
, Rundberget, Thomas
, Adolfsen, Pål
, Waaler, Thor Arnulf
in
Acetonitrile
/ Chromatography
/ Liquid chromatography
/ Preservation
/ Rivers
/ Rotenone
2018
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Fast and accurate on-site determination of rotenone in water during fish control treatments using liquid chromatography
by
Sandodden, Roar
, Sandvik, Morten
, Bardal, Helge
, Rundberget, Thomas
, Adolfsen, Pål
, Waaler, Thor Arnulf
in
Acetonitrile
/ Chromatography
/ Liquid chromatography
/ Preservation
/ Rivers
/ Rotenone
2018
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Fast and accurate on-site determination of rotenone in water during fish control treatments using liquid chromatography
Journal Article
Fast and accurate on-site determination of rotenone in water during fish control treatments using liquid chromatography
2018
Request Book From Autostore
and Choose the Collection Method
Overview
A fast, accurate and simple method using liquid chromatography (LC) with UV detection was used for the on-site determination of the piscicide rotenonein water during fish control treatments. Sample volumes of 10 to 40 µL were loaded onto a Waters XBridge™ C18 2.5 µm 3.0 x100 mm analytical column usinga mobile phase of water–acetonitrile (45:55) at a flow-rate of 0.5 mL/min. The method was evaluated using river and estuarine water spiked with rotenone(0.1–330 µg/L) and various preservation methods. The within-assay precision measured as relative standard deviation (RSD, n = 12) was 5.5 to 6.5% andthe between assay precision (RSD, n = 4) was 6.5 to 7.5%. The limit of quantification was 1 µg/L, below normal piscicidal treatment rates (5 to 200 µg/L)and regulatory limits (< 2 µg/L) generally considered safe. The analysis time was 6 min/sample allowing for real-time adjustment of rotenone dosages duringfish control treatments. The relatively small size (75×60×50 cm) of the LC system made it ideal for transportation and installation in remote treatment areas;it can be operated out of a small trailer in the field with electricity. Our studies indicate that the preservation of water samples with equal quantitiesof acetonitrile stabilizes rotenone indefinitely (> 170 days) if kept cool (4 °C) and in the dark. Although increased salinity decreased the recoveryof rotenone, sample filtration with Spin-X filter membranes negated the effect.
Publisher
Regional Euro-Asian Biological Invasions Centre
Subject
MBRLCatalogueRelatedBooks
This website uses cookies to ensure you get the best experience on our website.