MbrlCatalogueTitleDetail

Do you wish to reserve the book?
INTRACRANIAL ELECTROENCEPHALOGRAPHY WITH SUBDURAL GRID ELECTRODES
INTRACRANIAL ELECTROENCEPHALOGRAPHY WITH SUBDURAL GRID ELECTRODES
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
INTRACRANIAL ELECTROENCEPHALOGRAPHY WITH SUBDURAL GRID ELECTRODES
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
INTRACRANIAL ELECTROENCEPHALOGRAPHY WITH SUBDURAL GRID ELECTRODES
INTRACRANIAL ELECTROENCEPHALOGRAPHY WITH SUBDURAL GRID ELECTRODES

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
INTRACRANIAL ELECTROENCEPHALOGRAPHY WITH SUBDURAL GRID ELECTRODES
INTRACRANIAL ELECTROENCEPHALOGRAPHY WITH SUBDURAL GRID ELECTRODES
Journal Article

INTRACRANIAL ELECTROENCEPHALOGRAPHY WITH SUBDURAL GRID ELECTRODES

2008
Request Book From Autostore and Choose the Collection Method
Overview
Intracranial subdural grid monitoring is a useful diagnostic technique for surgical localization in patients with intractable partial epilepsy. The rationale for the present study was to assess the morbidity of intracranial recordings and the surgical outcomes. We retrospectively reviewed the clinical data for 189 unique patients undergoing 198 intracranial subdural grid monitoring sessions between 1996 and 2004 at a tertiary epilepsy center. The mean age of patients undergoing monitoring was 28 +/- 14 years. An average of 63 +/- 23 electrodes were inserted. The mean duration of monitoring was 8 +/- 4 days. Localization of an epileptogenic zone occurred in 156 sessions (79%) resulting in 136 resections (69%). There were 13 major complications (6.6%), including five infections and six hematomas. Three patients (1.5%) developed permanent deficits related to implantation. Sixty-two (47%) of 136 patients undergoing resection were seizure-free after resection. An additional 38 patients (28%) had a significant reduction in seizures. The mean follow-up was 51 +/- 30 months. The duration of monitoring, bone flap replacement, number of electrodes, and perioperative corticosteroids were not associated with infection or complication. Subdural grid monitoring for identification an epileptogenic focus is high yield, revealing a focus in 79% of monitoring sessions. Complications rarely result in permanent morbidity (1.5%). Surgical outcome indicated that 74% of patients experienced a favorable reduction in seizure tendency.