MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Echocardiographic parameters to predict inadequate defibrillation safety margin in patients receiving implantable cardioverter defibrillators for primary prevention
Echocardiographic parameters to predict inadequate defibrillation safety margin in patients receiving implantable cardioverter defibrillators for primary prevention
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Echocardiographic parameters to predict inadequate defibrillation safety margin in patients receiving implantable cardioverter defibrillators for primary prevention
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Echocardiographic parameters to predict inadequate defibrillation safety margin in patients receiving implantable cardioverter defibrillators for primary prevention
Echocardiographic parameters to predict inadequate defibrillation safety margin in patients receiving implantable cardioverter defibrillators for primary prevention

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Echocardiographic parameters to predict inadequate defibrillation safety margin in patients receiving implantable cardioverter defibrillators for primary prevention
Echocardiographic parameters to predict inadequate defibrillation safety margin in patients receiving implantable cardioverter defibrillators for primary prevention
Journal Article

Echocardiographic parameters to predict inadequate defibrillation safety margin in patients receiving implantable cardioverter defibrillators for primary prevention

2013
Request Book From Autostore and Choose the Collection Method
Overview
Background Implantable cardioverter defibrillators (ICDs) have become an important part of the management of patients with congestive heart failure. At the time of ICD implantation, ventricular fibrillation (VF) is induced to assess adequate energy required for defibrillation. There are multiple parameters which influence the defibrillation safety margin (DSM); however, these factors are not well-established when ICDs are implanted for the primary prevention of sudden cardiac death (SCD) in patients with severe systolic dysfunction. We evaluated multiple clinical and echocardiographic parameters as predictors of adequate DSM in patients referred for ICD implantation for the primary prevention of SCD. Methods We prospectively enrolled 41 patients for ICD implantation with clinical indications for the primary prevention of SCD. Two blinded independent readers evaluated the prespecified echocardiographic parameters. These included left ventricular (LV) mass, indices of right ventricular and LV systolic and diastolic functions, and LV geometric dimensions. Basic clinical demographics, including age, gender, comorbidities, and etiology of cardiomyopathy, were also evaluated. DSM was established using our standard protocol for defibrillation testing which includes VF with successful first shock terminating VF at a value at least 10 J below the maximum output of the implanted device. High defibrillation thresholds (DFT) were defined as >21 J. Results The mean age is 61.8 ± 14.7 years, with men comprising the majority of the patients (73 %). The only clinical variables which predicted the high DFT were age (in years) (54.5 ± 17.5 vs. 65.7 ± 11.3, p  = 0.044), QRS duration (in milliseconds) (116.0 ± 29.5 vs. 110.5 ± 21.8, p  = 0.03), LV mass (in grams) (241.0 ± 77.9 vs. 181.9 ± 52.3, p  = 0.006), and LV mass index (in grams per square meter) (111.1 ± 38.2 vs. 86.4 ± 21.1, p  = 0.02). On multivariate logistic regression analysis, LV mass was the only independent predictor of low DFT (≤22 J) in patients with ICD implanted for the primary prevention of SCD. Conclusion LV mass may help predict an adequate DSM in patients who are referred for ICD implantation for the primary prevention of SCD. These results may help distinguish the patients who may require high-energy devices prior to the implantation procedure. These results may help distinguish patients requiring high-energy devices, coils, or advanced programming prior to implantation and appropriate referral to electrophysiologists.