MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Assessing the Effectiveness of an Intelligent Algorithms-Based PII2 Controller in Enhancing the Quality of Power Output from a DFIG-Based Power System
Assessing the Effectiveness of an Intelligent Algorithms-Based PII2 Controller in Enhancing the Quality of Power Output from a DFIG-Based Power System
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Assessing the Effectiveness of an Intelligent Algorithms-Based PII2 Controller in Enhancing the Quality of Power Output from a DFIG-Based Power System
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Assessing the Effectiveness of an Intelligent Algorithms-Based PII2 Controller in Enhancing the Quality of Power Output from a DFIG-Based Power System
Assessing the Effectiveness of an Intelligent Algorithms-Based PII2 Controller in Enhancing the Quality of Power Output from a DFIG-Based Power System

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Assessing the Effectiveness of an Intelligent Algorithms-Based PII2 Controller in Enhancing the Quality of Power Output from a DFIG-Based Power System
Assessing the Effectiveness of an Intelligent Algorithms-Based PII2 Controller in Enhancing the Quality of Power Output from a DFIG-Based Power System
Journal Article

Assessing the Effectiveness of an Intelligent Algorithms-Based PII2 Controller in Enhancing the Quality of Power Output from a DFIG-Based Power System

2025
Request Book From Autostore and Choose the Collection Method
Overview
This paper proposes a novel methodology based on two intelligent algorithms for regulating the power output of a multi-rotor turbine system. A proportional-integral plus second-order integral regulator is utilized to regulate the energy output of an induction generator. The designed controller is characterized by its ease of configuration, cost-effectiveness, high robustness, and ease of implementation. The controller’s parameters are tuned using a genetic algorithm (GA) and a rooted tree optimization (RTO) algorithm, with the objective of maximizing operational performance and power quality. In accordance with the proposed design methodology, the optimal values for the parameters of the designed strategy are attained through the implementation of integral time-weighted absolute error (ITAE). The present controller has been designed to deviate from conventional controllers, and a comparison will be made between the two using MATLAB under various operating conditions. The operational performance was evaluated in comparison to the conventional algorithm in terms of current quality, torque ripples, threshold overshoot, system parameter changes, and so forth. The experimental results, as measured by the tests conducted, demonstrated that the proposed RTO-based regulator exhibited enhancements of up to 89.88% (traditional control) and 51.92% (GA) in active power ripples, 68.19% (compared to traditional control) in ITAE, 51.91% (traditional control) in reactive power overshoot, and 0.5% (compared to GA) in active power response time. Conversely, the proposed GA-based regulator yielded a steady-state error value that was 96.55% superior to the traditional approach and 86.48% more accurate than the RTO algorithm. Moreover, the efficacy of the RTO-based control system was found to be considerably augmented under variable system parameters. Total harmonic distortion improvements of 69% were observed compared to traditional control methods, and 1% compared to the GA technique. The findings of this study offer significant insights into enhancing the robustness of multi-rotor turbine systems and improving power quality.