Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Application of the Sinusoidal Voltage for Detection of the Resonance in Inductive Voltage Transformers
by
Stano, Ernest
, Kaczmarek, Michal
in
Accuracy
/ higher harmonics
/ inductive voltage transformer
/ Laboratories
/ non-sinusoidal medium voltage
/ resonance for harmonic
/ sinusoidal voltage of increased frequency
/ Used equipment
2021
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Application of the Sinusoidal Voltage for Detection of the Resonance in Inductive Voltage Transformers
by
Stano, Ernest
, Kaczmarek, Michal
in
Accuracy
/ higher harmonics
/ inductive voltage transformer
/ Laboratories
/ non-sinusoidal medium voltage
/ resonance for harmonic
/ sinusoidal voltage of increased frequency
/ Used equipment
2021
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Application of the Sinusoidal Voltage for Detection of the Resonance in Inductive Voltage Transformers
by
Stano, Ernest
, Kaczmarek, Michal
in
Accuracy
/ higher harmonics
/ inductive voltage transformer
/ Laboratories
/ non-sinusoidal medium voltage
/ resonance for harmonic
/ sinusoidal voltage of increased frequency
/ Used equipment
2021
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Application of the Sinusoidal Voltage for Detection of the Resonance in Inductive Voltage Transformers
Journal Article
Application of the Sinusoidal Voltage for Detection of the Resonance in Inductive Voltage Transformers
2021
Request Book From Autostore
and Choose the Collection Method
Overview
In the case of the inductive voltage transformer (VT), the resonance phenomenon may be the main reason for its poor transformation accuracy of the non-sinusoidal voltage. This problem mainly results from the leakage inductance and the parasitic capacitance of its primary winding. The application of the sinusoidal voltage with a frequency from 20 Hz to 20 kHz presented in this study ensures proper identification of the resonance frequencies of the medium-voltage (MV) inductive VTs. The results are consistent with the values obtained in the reference condition at their nominal primary voltage. Therefore, it is proven that the proposed solution is effective in all cases. The influence of the main frequency variation of the non-sinusoidal primary voltage on the resonance properties of the inductive VT is also studied. Moreover, the tests indicate that the capacitance of the load of the secondary winding may cause a decrease in their resonance frequency.