Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Scleral Buckling with a Non-Contact Wide-Angle Viewing System
by
Koytak, Arif
, Ucar, Didar
, Aras, Cengiz
, Yetik, Huseyin
in
Adult
/ Aged
/ Biological and medical sciences
/ Female
/ Fiber Optic Technology
/ Follow-Up Studies
/ Fundus Oculi
/ Humans
/ Male
/ Medical sciences
/ Middle Aged
/ Miscellaneous
/ Ophthalmology
/ Ophthalmoscopy - methods
/ Original Paper
/ Prospective Studies
/ Retinal Detachment - surgery
/ Retinopathies
/ Scleral Buckling
/ Silicone Oils - administration & dosage
/ Treatment Outcome
/ Vitrectomy
/ Young Adult
2012
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Scleral Buckling with a Non-Contact Wide-Angle Viewing System
by
Koytak, Arif
, Ucar, Didar
, Aras, Cengiz
, Yetik, Huseyin
in
Adult
/ Aged
/ Biological and medical sciences
/ Female
/ Fiber Optic Technology
/ Follow-Up Studies
/ Fundus Oculi
/ Humans
/ Male
/ Medical sciences
/ Middle Aged
/ Miscellaneous
/ Ophthalmology
/ Ophthalmoscopy - methods
/ Original Paper
/ Prospective Studies
/ Retinal Detachment - surgery
/ Retinopathies
/ Scleral Buckling
/ Silicone Oils - administration & dosage
/ Treatment Outcome
/ Vitrectomy
/ Young Adult
2012
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Scleral Buckling with a Non-Contact Wide-Angle Viewing System
by
Koytak, Arif
, Ucar, Didar
, Aras, Cengiz
, Yetik, Huseyin
in
Adult
/ Aged
/ Biological and medical sciences
/ Female
/ Fiber Optic Technology
/ Follow-Up Studies
/ Fundus Oculi
/ Humans
/ Male
/ Medical sciences
/ Middle Aged
/ Miscellaneous
/ Ophthalmology
/ Ophthalmoscopy - methods
/ Original Paper
/ Prospective Studies
/ Retinal Detachment - surgery
/ Retinopathies
/ Scleral Buckling
/ Silicone Oils - administration & dosage
/ Treatment Outcome
/ Vitrectomy
/ Young Adult
2012
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Scleral Buckling with a Non-Contact Wide-Angle Viewing System
Journal Article
Scleral Buckling with a Non-Contact Wide-Angle Viewing System
2012
Request Book From Autostore
and Choose the Collection Method
Overview
Purpose: To assess the outcome of scleral buckling surgery using a non-contact wide-angle viewing system for fundus visualization in patients with rhegmatogenous retinal detachment without proliferative vitreoretinopathy. Patients and Methods: Sixteen eyes of 16 patients underwent scleral buckling using a non-contact wide-angle viewing system combined with a 25-gauge illumination fibre inserted into the sclera at the pars plana. Results: The mean age of the patients was 53.6 ± 13.7 years and the mean follow-up time was 13.4 ± 2.8 months. Retinal reattachment was achieved in 13 of the 16 eyes (81%). Three eyes underwent vitrectomy with silicone oil injection because of development of proliferative vitreoretinopathy in 2 eyes and scleral perforation due to excessive indentation during cryoretinopexy in 1 eye. Two eyes developed limited subretinal haemorrhage during subretinal fluid drainage. Conclusion: Simultaneous use of a non-contact wide-angle viewing system combined with a 25-gauge light fibre illumination for fundus visualization brings the advantages of microsurgery and indirect ophthalmoscopy into scleral buckling surgery.
Publisher
Karger,S. Karger AG
This website uses cookies to ensure you get the best experience on our website.