MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Advanced Surface Ablation With a New Software for the Reduction of Ablation Irregularities
Advanced Surface Ablation With a New Software for the Reduction of Ablation Irregularities
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Advanced Surface Ablation With a New Software for the Reduction of Ablation Irregularities
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Advanced Surface Ablation With a New Software for the Reduction of Ablation Irregularities
Advanced Surface Ablation With a New Software for the Reduction of Ablation Irregularities

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Advanced Surface Ablation With a New Software for the Reduction of Ablation Irregularities
Advanced Surface Ablation With a New Software for the Reduction of Ablation Irregularities
Journal Article

Advanced Surface Ablation With a New Software for the Reduction of Ablation Irregularities

2017
Request Book From Autostore and Choose the Collection Method
Overview
To compare visual outcomes and postoperative aberrations after surface ablation performed with a 750-Hz versus a 1,050-Hz excimer laser coupled with an ablation software designed to reduce corneal surface irregularity. Retrospective comparative trial of myopic eyes that had refractive surgery consecutively treated with transepithelial advanced surface ablation with a 750-Hz excimer laser (750 group) versus a 1,050-Hz excimer laser coupled with the Smart Pulse Technology ablation software (SPT group). The SPT algorithm is a laser pulse technology software aimed at reducing surface irregularity of the stromal bed at the end of treatment. The authors evaluated the effect of this smoothing on final visual acuity. Patients were observed for 6 months. A total of 139 eyes in the 750 group and 40 eyes in the SPT group were evaluated. Epidemiological and preoperative refractive data of the two groups were comparable. Uncorrected distance visual acuity improved with time and was significantly better in the SPT group (-0.04 ± 0.61 logMAR for the SPT group vs 0.02 ± 0.78 logMAR for the 750 group) (P < .001). At 6 months, 55% versus 21% achieved 20/16 or better (P = .005) and 90% versus 65% achieved 20/20 or better (P = .019) visual acuity in the SPT and 750 groups, respectively. Corrected distance visual acuity improved with time and appeared to be influenced by group (P = .054), with better results in the SPT group. Coma and trefoil improved significantly with time in a similar manner in both groups. Surface ablation with the 1,050-Hz excimer laser and SPT software, aimed at reducing the final superficial stromal irregularity, led to improvement of 6-month uncorrected visual acuity. [J Refract Surg. 2017;33(2):89-95.].