MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Changes in spectral parameters of corneal pulse following canaloplasty
Changes in spectral parameters of corneal pulse following canaloplasty
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Changes in spectral parameters of corneal pulse following canaloplasty
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Changes in spectral parameters of corneal pulse following canaloplasty
Changes in spectral parameters of corneal pulse following canaloplasty

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Changes in spectral parameters of corneal pulse following canaloplasty
Changes in spectral parameters of corneal pulse following canaloplasty
Journal Article

Changes in spectral parameters of corneal pulse following canaloplasty

2019
Request Book From Autostore and Choose the Collection Method
Overview
PurposeTo ascertain whether changes in the spectral content of the corneal pulse (CP) signal, measured in vivo in primary open-angle glaucoma (POAG) patients, indirectly reflect changes in corneal biomechanics after canaloplasty.MethodsFifteen eyes of 15 POAG patients who underwent canaloplasty combined with phacoemulsification were enrolled. Standard ophthalmic examinations were conducted before washout, pre-operatively, at days 1, 7, and 1, 3, 6, and 12 months after surgery. Non-contact measurements of the CP signal were performed at pre-washout, pre-operatively, and at 3, 6, and 12 months post-operatively. Then, amplitudes of the CP first five harmonics associated with the heart rate were estimated. Temporal changes of all considered parameters were tested at a Bonferroni-adjusted significance level set to 0.005.ResultsA decrease in the amplitude of the first harmonic and an increase in the normalized amplitude of the third harmonic (ACP3n) of the CP signal were noticed between the pre-washout and the pre-operative stages (p = 0.003 and p = 0.004, respectively). This corresponds to an increase in median intraocular pressure (IOP) values by 6.0 mmHg (p = 0.0045). After surgery, ACP3n reached the highest value at 3 months post-operatively, compared with pre-washout level (p = 0.0045).ConclusionsAlterations in corneoscleral stiffness caused by surgery are reflected in changes in the ACP3n value. Hence, post-operative corneal biomechanics could be monitored indirectly by this supporting indicator that can be used to estimate the time at which measures of IOP are no longer biased by the changed cornea boundary conditions caused by canaloplasty.Clinical Trials RegistrationNCT02908633
Publisher
Springer Nature B.V