Maneuvering balloon occlusion technique to deflect LV lead into a target branch during CRT implantation
by
Ahmed, Adil
, Al Ghamdi, Saleh
, Dagriri, K.
, Al Khadra, Ayman
, Al Fagih, Ahmed
in
Angiography - methods
/ Balloon Occlusion - methods
/ Cardiac Pacing, Artificial - methods
/ Cardiology
/ Cardiomyopathy, Dilated - diagnostic imaging
/ Cardiomyopathy, Dilated - therapy
/ Case Report
/ Case reports
/ Combined Modality Therapy
/ Coronary Sinus - diagnostic imaging
/ Female
/ Follow-Up Studies
/ Humans
/ Medicine
/ Medicine & Public Health
/ Middle Aged
/ Pacemaker, Artificial
/ Risk Assessment
/ Severity of Illness Index
/ Treatment Outcome
2010
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Maneuvering balloon occlusion technique to deflect LV lead into a target branch during CRT implantation
by
Ahmed, Adil
, Al Ghamdi, Saleh
, Dagriri, K.
, Al Khadra, Ayman
, Al Fagih, Ahmed
in
Angiography - methods
/ Balloon Occlusion - methods
/ Cardiac Pacing, Artificial - methods
/ Cardiology
/ Cardiomyopathy, Dilated - diagnostic imaging
/ Cardiomyopathy, Dilated - therapy
/ Case Report
/ Case reports
/ Combined Modality Therapy
/ Coronary Sinus - diagnostic imaging
/ Female
/ Follow-Up Studies
/ Humans
/ Medicine
/ Medicine & Public Health
/ Middle Aged
/ Pacemaker, Artificial
/ Risk Assessment
/ Severity of Illness Index
/ Treatment Outcome
2010
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Maneuvering balloon occlusion technique to deflect LV lead into a target branch during CRT implantation
by
Ahmed, Adil
, Al Ghamdi, Saleh
, Dagriri, K.
, Al Khadra, Ayman
, Al Fagih, Ahmed
in
Angiography - methods
/ Balloon Occlusion - methods
/ Cardiac Pacing, Artificial - methods
/ Cardiology
/ Cardiomyopathy, Dilated - diagnostic imaging
/ Cardiomyopathy, Dilated - therapy
/ Case Report
/ Case reports
/ Combined Modality Therapy
/ Coronary Sinus - diagnostic imaging
/ Female
/ Follow-Up Studies
/ Humans
/ Medicine
/ Medicine & Public Health
/ Middle Aged
/ Pacemaker, Artificial
/ Risk Assessment
/ Severity of Illness Index
/ Treatment Outcome
2010
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Maneuvering balloon occlusion technique to deflect LV lead into a target branch during CRT implantation
Journal Article
Maneuvering balloon occlusion technique to deflect LV lead into a target branch during CRT implantation
2010
Request Book From Autostore
and Choose the Collection Method
Overview
Implantation of specifically designed left ventricular (LV) lead is a relatively complex procedure that depends on the anatomy of the coronary veins, available instrumentation, and experience of the operator. In patients with dilated cardiomyopathy (DCM) tortuosity of the selected branch of coronary sinus (CS) leads to difficult or failed LV placement. A case study of a 45-year-old woman with DCM requiring lead placement is presented here. To plan for proper LV lead positioning, CS angiography was obtained through right femoral vein approach with preshaped long sheath (SJM, SL3) and occlusive balloon. For successful implant of LV lead, with no viable alternatives available, the tortuosity of the lateral and posterolateral branch were overcome by advancing and inflating the balloon in the main CS to deflect LV lead into the target branch. A unipolar LV lead (Medtronic 4193) was finally placed in a true posterolateral position with excellent sensing and pacing threshold without phrenic nerve stimulation.
Publisher
Springer US,Springer Nature B.V
This website uses cookies to ensure you get the best experience on our website.