Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Percutaneous needle biopsy of mediastinal masses under C-arm conebeam CT guidance: diagnostic performance and safety
by
Floridi, Chiara
, Capasso, Raffaella
, Reginelli, Alfonso
, Barile, Antonio
, Zappia, Marcello
, Brunese, Luca
, Pesapane, Filippo
, Caranci, Ferdinando
, Fumarola, Enrico
in
Adolescent
/ Adult
/ Aged
/ Aged, 80 and over
/ Biopsy, Needle - methods
/ Female
/ Hematology
/ Humans
/ Image-Guided Biopsy - methods
/ Internal Medicine
/ Male
/ Mediastinal Neoplasms - diagnostic imaging
/ Mediastinal Neoplasms - pathology
/ Medicine
/ Medicine & Public Health
/ Middle Aged
/ New Advances in Interventional Oncology: State of the Art
/ Oncology
/ Original Paper
/ Pathology
/ Retrospective Studies
/ Tomography, X-Ray Computed - methods
/ Young Adult
2017
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Percutaneous needle biopsy of mediastinal masses under C-arm conebeam CT guidance: diagnostic performance and safety
by
Floridi, Chiara
, Capasso, Raffaella
, Reginelli, Alfonso
, Barile, Antonio
, Zappia, Marcello
, Brunese, Luca
, Pesapane, Filippo
, Caranci, Ferdinando
, Fumarola, Enrico
in
Adolescent
/ Adult
/ Aged
/ Aged, 80 and over
/ Biopsy, Needle - methods
/ Female
/ Hematology
/ Humans
/ Image-Guided Biopsy - methods
/ Internal Medicine
/ Male
/ Mediastinal Neoplasms - diagnostic imaging
/ Mediastinal Neoplasms - pathology
/ Medicine
/ Medicine & Public Health
/ Middle Aged
/ New Advances in Interventional Oncology: State of the Art
/ Oncology
/ Original Paper
/ Pathology
/ Retrospective Studies
/ Tomography, X-Ray Computed - methods
/ Young Adult
2017
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Percutaneous needle biopsy of mediastinal masses under C-arm conebeam CT guidance: diagnostic performance and safety
by
Floridi, Chiara
, Capasso, Raffaella
, Reginelli, Alfonso
, Barile, Antonio
, Zappia, Marcello
, Brunese, Luca
, Pesapane, Filippo
, Caranci, Ferdinando
, Fumarola, Enrico
in
Adolescent
/ Adult
/ Aged
/ Aged, 80 and over
/ Biopsy, Needle - methods
/ Female
/ Hematology
/ Humans
/ Image-Guided Biopsy - methods
/ Internal Medicine
/ Male
/ Mediastinal Neoplasms - diagnostic imaging
/ Mediastinal Neoplasms - pathology
/ Medicine
/ Medicine & Public Health
/ Middle Aged
/ New Advances in Interventional Oncology: State of the Art
/ Oncology
/ Original Paper
/ Pathology
/ Retrospective Studies
/ Tomography, X-Ray Computed - methods
/ Young Adult
2017
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Percutaneous needle biopsy of mediastinal masses under C-arm conebeam CT guidance: diagnostic performance and safety
Journal Article
Percutaneous needle biopsy of mediastinal masses under C-arm conebeam CT guidance: diagnostic performance and safety
2017
Request Book From Autostore
and Choose the Collection Method
Overview
The aim of this study is to evaluate the feasibility of percutaneous needle biopsy of mediastinal masses under conebeam computed tomography (CBCT) and “XperGuide” navigation guidance. From September 2013 to April 2016, 40 patients (25 men and 15 women; mean age 52.5 years; range 18.7–86.4 years) with 40 mediastinal masses underwent CBCT-/”XperGuide”-guided percutaneous needle biopsies. Technical success, sensibility, specificity, positive predictive value (ppv), negative predictive value (npv) and complications rate were evaluated. Technical success evaluated as the correct positioning of the needle inside the lesion was 100%. Based on histopathological diagnosis, 2 of 40 biopsies (5%) resulted a false negative. Diagnostic accuracy was 95%, sensitivity was 95%, specificity was 100%, ppv was 100%, and npv was 33%. The mean total procedure time was 32 min (range 15–60 min) revealing a reduction in time comparing the first group of 20 patients (mean time 45 min) with the last group of 20 patients (mean time 17 min). No major complications were recorded. Only three patients (7.5%) had mild pneumothorax as demonstrated by post-procedural CBCT, resolved spontaneously. CBCT/“XperGuide” navigation system is a new, safe and accurate technique that can be used as guidance for mediastinal mass biopsies. It also permits the use of CT machines for diagnostic examinations relieving them from interventional procedures burden.
Publisher
Springer US,Springer Nature B.V
This website uses cookies to ensure you get the best experience on our website.