Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Effectiveness and safety of EUS-guided choledochoduodenostomy using lumen-apposing metal stents (LAMS): a systematic review and meta-analysis
by
Irani Shayan
, Krishnamoorthi Rajesh
, Larsen, Michael
, Kozarek, Richard
, Ross, Andrew
, Dasari, Chandra S
, Jayaraj Mahendran
, Thoguluva Chandrasekar Viveksandeep
, Harshith, Priyan
, Law, Joanna
in
Endoscopy
/ Meta-analysis
/ Performance evaluation
/ Stents
/ Success
/ Systematic review
2020
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Effectiveness and safety of EUS-guided choledochoduodenostomy using lumen-apposing metal stents (LAMS): a systematic review and meta-analysis
by
Irani Shayan
, Krishnamoorthi Rajesh
, Larsen, Michael
, Kozarek, Richard
, Ross, Andrew
, Dasari, Chandra S
, Jayaraj Mahendran
, Thoguluva Chandrasekar Viveksandeep
, Harshith, Priyan
, Law, Joanna
in
Endoscopy
/ Meta-analysis
/ Performance evaluation
/ Stents
/ Success
/ Systematic review
2020
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Effectiveness and safety of EUS-guided choledochoduodenostomy using lumen-apposing metal stents (LAMS): a systematic review and meta-analysis
by
Irani Shayan
, Krishnamoorthi Rajesh
, Larsen, Michael
, Kozarek, Richard
, Ross, Andrew
, Dasari, Chandra S
, Jayaraj Mahendran
, Thoguluva Chandrasekar Viveksandeep
, Harshith, Priyan
, Law, Joanna
in
Endoscopy
/ Meta-analysis
/ Performance evaluation
/ Stents
/ Success
/ Systematic review
2020
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Effectiveness and safety of EUS-guided choledochoduodenostomy using lumen-apposing metal stents (LAMS): a systematic review and meta-analysis
Journal Article
Effectiveness and safety of EUS-guided choledochoduodenostomy using lumen-apposing metal stents (LAMS): a systematic review and meta-analysis
2020
Request Book From Autostore
and Choose the Collection Method
Overview
BackgroundEndoscopic ultrasound-guided choledochoduodenostomy (CDD) is emerging as an alternative technique for biliary drainage in patients who fail conventional endoscopic retrograde cholangiopancreatography (ERCP). The lumen-apposing metal stents (LAMS) are being increasingly used for CDD. We performed a systematic review and meta-analysis to evaluate the effectiveness and safety of CDD using LAMS.MethodsWe performed a systematic search of multiple databases through May 2019 to identify studies on CDD using covered self-expanding metal stents. Pooled rates of technical success, clinical success, adverse events, and recurrent jaundice associated with CDD using LAMS were estimated. A subgroup analysis was performed based on use of LAMS with electrocautery-enhanced delivery system (EC-LAMS).ResultsSeven studies on CDD using LAMS (with 284 patients) were included in the meta-analysis. Pooled rates of technical and clinical success (per-protocol analysis) were 95.7% (95% CI 93.2–98.1) and 95.9% (95% CI 92.8–98.9), respectively. Pooled rate of post-procedure adverse events was 5.2% (95% CI 2.6–7.9). Pooled rate of recurrent jaundice was 8.7% (95% CI 4.5–12.8).On subgroup analysis of CDD using EC-LAMS (5 studies with 201 patients), the pooled rates of technical and clinical success (per-protocol analysis) were 93.8% (95% CI 90.4–97.1) and 95.9% (95% CI 91.9–99.9), respectively. Pooled rate of post-procedure adverse events was 5.6% (95% CI 1.7–9.5). Pooled rate of recurrent jaundice was 11.3% (95% CI 6.9–15.7). Heterogeneity (I2) was low to moderate in the analyses.ConclusionCDD using LAMS/EC-LAMS is an effective and safe technique for biliary decompression in patients who failed ERCP. Further studies are needed to assess CDD using LAMS as primary treatment modality for biliary obstruction.
Publisher
Springer Nature B.V
Subject
This website uses cookies to ensure you get the best experience on our website.