MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Endoscopic treatment of renal and ureteral stones using the new Cyber Ho generator with Magneto technology: the first clinical experience from a multicenter study
Endoscopic treatment of renal and ureteral stones using the new Cyber Ho generator with Magneto technology: the first clinical experience from a multicenter study
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Endoscopic treatment of renal and ureteral stones using the new Cyber Ho generator with Magneto technology: the first clinical experience from a multicenter study
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Endoscopic treatment of renal and ureteral stones using the new Cyber Ho generator with Magneto technology: the first clinical experience from a multicenter study
Endoscopic treatment of renal and ureteral stones using the new Cyber Ho generator with Magneto technology: the first clinical experience from a multicenter study

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Endoscopic treatment of renal and ureteral stones using the new Cyber Ho generator with Magneto technology: the first clinical experience from a multicenter study
Endoscopic treatment of renal and ureteral stones using the new Cyber Ho generator with Magneto technology: the first clinical experience from a multicenter study
Journal Article

Endoscopic treatment of renal and ureteral stones using the new Cyber Ho generator with Magneto technology: the first clinical experience from a multicenter study

2025
Request Book From Autostore and Choose the Collection Method
Overview
Purpose A novel Ho: YAG laser generator incorporating Magneto pulse modulation technology has been developed to enhance lithotripsy performance. This study evaluates the safety and effectiveness of the Holmium: YAG Cyber Ho generator with Magneto technology (Quanta System ® ) for the endoscopic treatment of renal and ureteral stones. Materials and methods An observational multicentric study was conducted on 55 prospectively enrolled patients with ureteral and renal stones who underwent endoscopic lithotripsy using the new Ho: YAG laser with Magneto pulse modulation technology. Recorded parameters included stone volume, density, laser-on time (LOT), and laser settings optimized for Magneto use. Outcome metrics included ablation speed (mm³/s) and energy consumption (J/mm³), while the stone-free rate (SFR) and complication rate were also assessed. The perceived effectiveness of lithotripsy and retropulsion were evaluated using a 5-point Likert scale. Results Included patients had a median age of 57 years (IQR 48–65). The median stone volume was 948 mm³ (IQR 107–3091), and the median stone density was 900 HU (IQR 750–1105). Stones were located in the ureter in 21 cases (38%), in the lower calyx in 13 cases (24%), and in the upper/mid calyx in 21 cases (38%). The median laser-on time was 16 min (IQR 5–17). Laser settings showed consistent performance, with a median energy of 0.8 J (IQR 0.8–0.8), a frequency of 10 Hz (IQR 10–10), and an average power of 8 W (IQR 8–10). Lithotripsy performance was reflected by a median energy consumption of 14.8 J/mm³ (IQR 11.9–24.3) and an ablation speed of 0.6 mm³/s (IQR 0.4–0.7). The stone-free rate (SFR) was 94.5%. 3.6% of patients experienced Clavien-Dindo grade 1–2 complications, and no severe complications (grade 3–4) were reported. Subjective efficacy was rated as “outstanding” and “very good” in 58.2% and 36.4% of cases, respectively, while retropulsion was subjectively evaluated as “absent” and “very low” in 91.0% and 9.0% of cases, respectively. Conclusions Endoscopic treatment of renal and ureteral stones using the Cyber Ho generator with the new Magneto pulse modulation technology is safe and effective in this preliminary report. High ablation efficiency and a satisfying anti-retropulsion effect have been reported, potentially leading to faster treatment, higher stone-free rates (SFR), and a lower need for second-stage procedures. Further studies are required to fully evaluate this technology.