MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Unipolar Arc Ignited Partial Discharge for 650-V AlGaN/GaN HEMTs during the DC Breakdown Voltage Measurement
Unipolar Arc Ignited Partial Discharge for 650-V AlGaN/GaN HEMTs during the DC Breakdown Voltage Measurement
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Unipolar Arc Ignited Partial Discharge for 650-V AlGaN/GaN HEMTs during the DC Breakdown Voltage Measurement
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Unipolar Arc Ignited Partial Discharge for 650-V AlGaN/GaN HEMTs during the DC Breakdown Voltage Measurement
Unipolar Arc Ignited Partial Discharge for 650-V AlGaN/GaN HEMTs during the DC Breakdown Voltage Measurement

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Unipolar Arc Ignited Partial Discharge for 650-V AlGaN/GaN HEMTs during the DC Breakdown Voltage Measurement
Unipolar Arc Ignited Partial Discharge for 650-V AlGaN/GaN HEMTs during the DC Breakdown Voltage Measurement
Journal Article

Unipolar Arc Ignited Partial Discharge for 650-V AlGaN/GaN HEMTs during the DC Breakdown Voltage Measurement

2022
Request Book From Autostore and Choose the Collection Method
Overview
Without the Fluorinert solution and proper pad design, the high–voltage (HV) transistor used during the DC breakdown voltage (Vbk) measurement might be damaged by the partial discharge (PD) in the air if its Vbk is close to one thousand volts or more. From the waveform measurement, the PD in the air occurred at 650 V HV GaN HEMTs during the Vbk measurement, it is ignited by the unipolar arc, and it is not ignited by the avalanche breakdown. This is based on the fact that the current falls below zero ampere to become a negative current, and the voltage rises so that it is higher than the setting voltage of the DC meter at the onset of the PD, thus corresponding with the electrons, leaving the plasma to cathode, and enabling a build–in potential to exist in the plasma. Then, the PD ignites because the current starts to rise in order to allow for a positive spike current; the voltage level subsequently falls and a lower voltage reading is obtained.