Comparison of specular microscopy and ultrasound pachymetry before and after cataract surgery
by
López-Miguel, Alberto
, Holgueras, Alfredo
, Maldonado, Miguel J.
, Sanchidrián, María
, Fernández, Itziar
in
Aged
/ Aged, 80 and over
/ Cornea
/ Cornea - diagnostic imaging
/ Corneal Edema - diagnosis
/ Corneal Pachymetry - methods
/ Female
/ Follow-Up Studies
/ Humans
/ Male
/ Medicine
/ Medicine & Public Health
/ Microscopy - methods
/ Middle Aged
/ Ophthalmology
/ Phacoemulsification - adverse effects
/ Postoperative Complications
/ Postoperative Period
/ Preoperative Period
/ Reproducibility of Results
/ Time Factors
2017
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Comparison of specular microscopy and ultrasound pachymetry before and after cataract surgery
by
López-Miguel, Alberto
, Holgueras, Alfredo
, Maldonado, Miguel J.
, Sanchidrián, María
, Fernández, Itziar
in
Aged
/ Aged, 80 and over
/ Cornea
/ Cornea - diagnostic imaging
/ Corneal Edema - diagnosis
/ Corneal Pachymetry - methods
/ Female
/ Follow-Up Studies
/ Humans
/ Male
/ Medicine
/ Medicine & Public Health
/ Microscopy - methods
/ Middle Aged
/ Ophthalmology
/ Phacoemulsification - adverse effects
/ Postoperative Complications
/ Postoperative Period
/ Preoperative Period
/ Reproducibility of Results
/ Time Factors
2017
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Comparison of specular microscopy and ultrasound pachymetry before and after cataract surgery
by
López-Miguel, Alberto
, Holgueras, Alfredo
, Maldonado, Miguel J.
, Sanchidrián, María
, Fernández, Itziar
in
Aged
/ Aged, 80 and over
/ Cornea
/ Cornea - diagnostic imaging
/ Corneal Edema - diagnosis
/ Corneal Pachymetry - methods
/ Female
/ Follow-Up Studies
/ Humans
/ Male
/ Medicine
/ Medicine & Public Health
/ Microscopy - methods
/ Middle Aged
/ Ophthalmology
/ Phacoemulsification - adverse effects
/ Postoperative Complications
/ Postoperative Period
/ Preoperative Period
/ Reproducibility of Results
/ Time Factors
2017
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Comparison of specular microscopy and ultrasound pachymetry before and after cataract surgery
Journal Article
Comparison of specular microscopy and ultrasound pachymetry before and after cataract surgery
2017
Request Book From Autostore
and Choose the Collection Method
Overview
Purpose
To compare specular microscopy (Topcon SP-3000P, Topcon Corporation, Tokyo, Japan) and ultrasound (US) technology when evaluating central corneal thickness (CCT) prior to and after phacoemulsification.
Methods
Corneal edema was assessed in phacoemulsification patients due to senile cataract by measuring CCT preoperatively and 1 day, 1 month, and 3 months postoperatively. Bland–Altman analysis was performed to assess interchangeability between pachymetry techniques for each visit. Repeated measures analysis of variance was performed to evaluate variation in CCT agreement depending on the degree of corneal edema.
Results
One hundred and eighteen patients aged 73.9 ± 10.1 years were recruited. Topcon SP-3000P provided significant (
p
< 0.0001) lower CCT values than US with and without induced corneal edema. Mean differences between CCT techniques for baseline, 1 day, 1 month and 3 months after cataract surgery were −28.9 ± 22.6, −30.5 ± 41.4, −32.3 ± 16.2 and −33.0 ± 16.9 μm, respectively. The systematic bias observed was not significantly different among the 4 visits (p = 0.59). The estimated limits of agreement (based on 1.96 standard deviation) were substantial, being 90.5, 165.8, 64.9 and 67.5 um at baseline, 1 day and 1 and 3 months.
Conclusions
Topcon SP-3000P provides similar systematic bias in comparison with US technique for CCT measurements regardless of the degree of corneal edema after phacoemulsification, which should be reduced after applying a constant calibration adjustment of ∼30 μm. However, interchangeability between techniques may be still limited by the notable random measurement error.