MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Use of a custom alignment guide to improve glenoid component position in total shoulder arthroplasty
Use of a custom alignment guide to improve glenoid component position in total shoulder arthroplasty
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Use of a custom alignment guide to improve glenoid component position in total shoulder arthroplasty
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Use of a custom alignment guide to improve glenoid component position in total shoulder arthroplasty
Use of a custom alignment guide to improve glenoid component position in total shoulder arthroplasty

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Use of a custom alignment guide to improve glenoid component position in total shoulder arthroplasty
Use of a custom alignment guide to improve glenoid component position in total shoulder arthroplasty
Journal Article

Use of a custom alignment guide to improve glenoid component position in total shoulder arthroplasty

2013
Request Book From Autostore and Choose the Collection Method
Overview
Purpose Total and reverse total shoulder arthroplasty (TSA) are used to treat patients with glenohumeral joint osteoarthritis. The revision rate remains high compared with hip and knee arthroplasty. Glenoid component loosening is an important complication and may be caused by poor positioning of the component. We aimed to evaluate the safety and accuracy of a custom glenoid jig created using preoperative computed tomography (CT) imaging with 3D modelling for glenoid component implantation. Methods Preoperative CT scans of each shoulder ( N  = 7) were obtained. Implants were virtually aligned and custom templates were created for intraoperative use. A two-part custom jig was manufactured for alignment of the central peg and the peripheral screws. Three-dimensional orientation of the component and screws was evaluated in postoperative CT scans. The difference between the preoperative plan and the result was then calculated. Results No technical difficulties or complications occurred. The mean absolute difference between the planned alignment and the postoperative placement of the glenoid component in the three-dimensional space was 3.4 mm (SD = 1 mm). The total average difference for all screws ( N  = 10) was 6.3° (SD = 3.2°). Conclusion A CT-based custom glenoid component alignment can reliably guide the placement of the glenoid component during conventional and reverse TSA. This custom jig may be useful for optimizing glenoid component position in the setting of reverse and TSA. Level of evidence IV.