Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
A PLLA Coating Does Not Affect the Insertion Pressure or Frictional Behavior of a CI Electrode Array at Higher Insertion Speeds
by
Grabow, Niels
, Schraven, Sebastian P.
, Wulf, Katharina
, Mlynski, Robert
, Dohr, Dana
in
Arrays
/ Catheters
/ Coated electrodes
/ Coating effects
/ Coefficient of friction
/ Data acquisition
/ Drug delivery systems
/ Electrodes
/ Friction
/ Insertion
/ Mechanical properties
/ Polymer coatings
/ Polymers
/ Sensors
/ Transplants & implants
2022
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
A PLLA Coating Does Not Affect the Insertion Pressure or Frictional Behavior of a CI Electrode Array at Higher Insertion Speeds
by
Grabow, Niels
, Schraven, Sebastian P.
, Wulf, Katharina
, Mlynski, Robert
, Dohr, Dana
in
Arrays
/ Catheters
/ Coated electrodes
/ Coating effects
/ Coefficient of friction
/ Data acquisition
/ Drug delivery systems
/ Electrodes
/ Friction
/ Insertion
/ Mechanical properties
/ Polymer coatings
/ Polymers
/ Sensors
/ Transplants & implants
2022
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
A PLLA Coating Does Not Affect the Insertion Pressure or Frictional Behavior of a CI Electrode Array at Higher Insertion Speeds
by
Grabow, Niels
, Schraven, Sebastian P.
, Wulf, Katharina
, Mlynski, Robert
, Dohr, Dana
in
Arrays
/ Catheters
/ Coated electrodes
/ Coating effects
/ Coefficient of friction
/ Data acquisition
/ Drug delivery systems
/ Electrodes
/ Friction
/ Insertion
/ Mechanical properties
/ Polymer coatings
/ Polymers
/ Sensors
/ Transplants & implants
2022
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
A PLLA Coating Does Not Affect the Insertion Pressure or Frictional Behavior of a CI Electrode Array at Higher Insertion Speeds
Journal Article
A PLLA Coating Does Not Affect the Insertion Pressure or Frictional Behavior of a CI Electrode Array at Higher Insertion Speeds
2022
Request Book From Autostore
and Choose the Collection Method
Overview
To prevent endocochlear insertion trauma, the development of drug delivery coatings in the field of CI electrodes has become an increasing focus of research. However, so far, the effect of a polymer coating of PLLA on the mechanical properties, such as the insertion pressure and friction of an electrode array, has not been investigated. In this study, the insertion pressure of a PLLA-coated, 31.5-mm long standard electrode array was examined during placement in a linear cochlear model. Additionally, the friction coefficients between a PLLA-coated electrode array and a tissue simulating the endocochlear lining were acquired. All data were obtained at different insertion speeds (0.1, 0.5, 1.0, 1.5, and 2.0 mm/s) and compared with those of an uncoated electrode array. It was shown that both the maximum insertion pressure generated in the linear model and the friction coefficient of the PLLA-coated electrode did not depend on the insertion speed. At higher insertion speeds above 1.0 mm/s, the insertion pressure (1.268 ± 0.032 mmHg) and the friction coefficient (0.40 ± 0.15) of the coated electrode array were similar to those of an uncoated array (1.252 ± 0.034 mmHg and 0.36 ± 0.15). The present study reveals that a PLLA coating on cochlear electrode arrays has a negligible effect on the electrode array insertion pressure and the friction when higher insertion speeds are used compared with an uncoated electrode array. Therefore, PLLA is a suitable material to be used as a coating for CI electrode arrays and can be considered for a potential drug delivery system.
Publisher
MDPI AG,MDPI
This website uses cookies to ensure you get the best experience on our website.