Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Characteristics of unconnected upward leaders initiated from tall structures observed in Guangzhou
by
Chen, Luwen
, Chen, Shaodong
, Lu, Weitao
, Zhang, Yang
, Huang, Zhihui
, Zhang, Yijun
, Ma, Ying
, Gao, Yan
, Yin, Qiyuan
in
Atmospheric sciences
/ cloud-to-ground lightning
/ Earth sciences
/ Earth, ocean, space
/ Exact sciences and technology
/ Geophysics
/ inception height
/ inception time
/ Lightning
/ strike point
/ unconnected upward leader
2012
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Characteristics of unconnected upward leaders initiated from tall structures observed in Guangzhou
by
Chen, Luwen
, Chen, Shaodong
, Lu, Weitao
, Zhang, Yang
, Huang, Zhihui
, Zhang, Yijun
, Ma, Ying
, Gao, Yan
, Yin, Qiyuan
in
Atmospheric sciences
/ cloud-to-ground lightning
/ Earth sciences
/ Earth, ocean, space
/ Exact sciences and technology
/ Geophysics
/ inception height
/ inception time
/ Lightning
/ strike point
/ unconnected upward leader
2012
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Characteristics of unconnected upward leaders initiated from tall structures observed in Guangzhou
by
Chen, Luwen
, Chen, Shaodong
, Lu, Weitao
, Zhang, Yang
, Huang, Zhihui
, Zhang, Yijun
, Ma, Ying
, Gao, Yan
, Yin, Qiyuan
in
Atmospheric sciences
/ cloud-to-ground lightning
/ Earth sciences
/ Earth, ocean, space
/ Exact sciences and technology
/ Geophysics
/ inception height
/ inception time
/ Lightning
/ strike point
/ unconnected upward leader
2012
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Characteristics of unconnected upward leaders initiated from tall structures observed in Guangzhou
Journal Article
Characteristics of unconnected upward leaders initiated from tall structures observed in Guangzhou
2012
Request Book From Autostore
and Choose the Collection Method
Overview
Forty‐five unconnected upward leaders (UULs) occurred in 19 downward negative flashes are analyzed. Each observed UUL is initiated by a downward stepped leader before a new strike point is struck. For each UUL, several parameters are determined when possible mainly by using high‐speed images: inception height, inception time prior to return stroke (RS), horizontal distance from the flash's strike point, two‐dimensional (2D) distance between the nearest downward leader branch tip and the UUL's inception point at its inception time, 2D length, and 2D average propagation velocity. Their values range from 40 to 503 m (number of samples: 45), <0.1 to 1.32 ms (38), 20 m to 1.3 km (38), 99 to 578 m (21), 0.48 to 399 m (45), and 5.79 to 33.8 × 104 m s−1 (22), respectively. 86% (19/22) of the velocities are smaller than 1.7 × 105 m s−1. No UUL with an inception time prior to RS greater than 0.5 ms is initiated from a structure lower than 300 m. Those UULs with inception heights lower than 300 m seldom exhibit lengths longer than 50 m and only can be initiated by flashes within approximately 600 m, while those higher than 400 m can even reach several hundred meters and be initiated by flashes over 1 km away. The maximum distances for the downward leaders to attract the UULs with inception heights from 100 to 200 m, 200 to 300 m, and over 400 m are approximately 350 m, 450 m, and 600 m, respectively. Key Points Cases and statistical analysis of unconnected upward positive leaders Observation of lightning discharges striking a city with many tall structures The data can help us estimate the effect of downward leader on upward leader
Publisher
Blackwell Publishing Ltd,American Geophysical Union
This website uses cookies to ensure you get the best experience on our website.