Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Estimating 3D lumen centerlines of carotid arteries in free-hand acquisition ultrasound
by
Bosch, Johan G
, Schinkel, Arend F. L
, Akkus, Zeynettin
, Carvalho, Diego D. B
, van der Lugt, Aad
, Klein, Stefan
, ten Kate, Gerrit L
, Niessen, Wiro J
in
Algorithms
/ Annotations
/ Carotid arteries
/ Elliptic fitting
/ Estimation
/ Euclidean geometry
/ Image acquisition
/ Real time
/ Robustness
/ Spatial data
/ Ultrasonic imaging
/ Veins & arteries
2012
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Estimating 3D lumen centerlines of carotid arteries in free-hand acquisition ultrasound
by
Bosch, Johan G
, Schinkel, Arend F. L
, Akkus, Zeynettin
, Carvalho, Diego D. B
, van der Lugt, Aad
, Klein, Stefan
, ten Kate, Gerrit L
, Niessen, Wiro J
in
Algorithms
/ Annotations
/ Carotid arteries
/ Elliptic fitting
/ Estimation
/ Euclidean geometry
/ Image acquisition
/ Real time
/ Robustness
/ Spatial data
/ Ultrasonic imaging
/ Veins & arteries
2012
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Estimating 3D lumen centerlines of carotid arteries in free-hand acquisition ultrasound
by
Bosch, Johan G
, Schinkel, Arend F. L
, Akkus, Zeynettin
, Carvalho, Diego D. B
, van der Lugt, Aad
, Klein, Stefan
, ten Kate, Gerrit L
, Niessen, Wiro J
in
Algorithms
/ Annotations
/ Carotid arteries
/ Elliptic fitting
/ Estimation
/ Euclidean geometry
/ Image acquisition
/ Real time
/ Robustness
/ Spatial data
/ Ultrasonic imaging
/ Veins & arteries
2012
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Estimating 3D lumen centerlines of carotid arteries in free-hand acquisition ultrasound
Journal Article
Estimating 3D lumen centerlines of carotid arteries in free-hand acquisition ultrasound
2012
Request Book From Autostore
and Choose the Collection Method
Overview
PurposeThe purpose of this paper is to present a methodology to estimate the carotid artery lumen centerlines in ultrasound (US) images obtained in a free-hand examination. Challenging aspects here are speckle noise in US images, artifacts, and the lack of contrast in the direction orthogonal to the US beam direction.MethodAn algorithm based on a rough lumen segmentation obtained by robust ellipse fitting was developed to deal with these conditions and estimate the lumen center in 2D B-mode scans. In a free-hand sweep examination, continuous image acquisitions are performed through time when the radiologist moves the probe on the patient’s neck. The result is a series of images that show 2D cross-sections of the carotid’s morphology. A tracking sensor (Flock of Birds) was attached to the probe and both were connected to a PC executing the Stradwin software, which relates spatial information to the acquisition data of the US probe. The spatial information was combined with the 2D lumen center estimates to provide a centerline in 3D. For validation, 19 carotid scans from 15 different patients were scanned, their centerlines calculated by the algorithm and compared with results acquired by manual annotations.ResultsThe average Euclidean distance between both among all the examinations was 0.82 mm. For each examination, the percentage of these Euclidean distances below 2 mm was calculated; the average over all examinations was 92%.ConclusionAutomated 3D estimation of carotid artery lumen centerlines in free-hand real-time ultrasound is feasible and can be performed with high accuracy. The algorithm is robust enough to keep the centerlines inside the vessel, even in the absence of contrast in parts of the vessel wall.