MbrlCatalogueTitleDetail

Do you wish to reserve the book?
CMR for myocardial iron overload quantification: calibration curve from the MIOT Network
CMR for myocardial iron overload quantification: calibration curve from the MIOT Network
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
CMR for myocardial iron overload quantification: calibration curve from the MIOT Network
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
CMR for myocardial iron overload quantification: calibration curve from the MIOT Network
CMR for myocardial iron overload quantification: calibration curve from the MIOT Network

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
CMR for myocardial iron overload quantification: calibration curve from the MIOT Network
CMR for myocardial iron overload quantification: calibration curve from the MIOT Network
Journal Article

CMR for myocardial iron overload quantification: calibration curve from the MIOT Network

2020
Request Book From Autostore and Choose the Collection Method
Overview
ObjectivesR2* cardiac magnetic resonance (CMR) allows the non-invasive measurement of myocardial iron. We calibrated cardiac R2* values against myocardial tissue–measured iron concentration by using a segmental approach and we assessed the iron distribution.MethodsFive hearts of thalassemia patients were donated after death/transplantation to the CoreLab of the Myocardial Iron Overload in Thalassemia Network. A multislice multiecho R2* approach was adopted. After CMR, used as guidance, the heart was cut in three short-axis slices and each slice was cut into different equiangular segments according to AHA segmentation and differentiated into endocardial and epicardial layers. Tissue iron concentration was measured by atomic absorption spectrometer technique.ResultsFifty-five samples were used since only for two hearts all the 16 samples were analyzed. Mean iron concentration was 4.71 ± 4.67 mg/g dw. Segmental iron levels ranged from 0.24 to 13.78 mg/g dw. The coefficient of variability of iron for myocardial segments ranged from 8.08 to 24.54% (mean 13.49 ± 6.93%). Iron concentration was significantly higher in the epicardial than in the endocardial layer (5.99 ± 6.01 vs 4.84 ± 4.87 mg/g dw; p = 0.042). Four different circumferential regions (anterior, septal, inferior, and lateral) were defined. A circumferential heterogeneity was noted, with more iron in the anterior region, followed by the inferior region. The direct nonlinear fitting of R2* and [Fe] data led to the calibration curve: [Fe] = 0.0022 ∙ (R2*-ROI)1.462 (R-square = 0.956).ConclusionsOur data further validate R2* CMR using a segmental approach as a sensitive and early technique for quantifying iron distribution in the current clinical practice.Key Points• Calibration in humans for cardiovascular magnetic resonance R2* against myocardial iron concentration was provided.• A circumferential heterogeneity in cardiac iron distribution was detected: more iron was observed in the anterior region, followed by the inferior region. This finding corroborates the use of a segmental T2* CMR approach in the clinical practice to detect a heterogeneous iron distribution.• The comparison between the cardiac T2* values obtained with the region-based and the pixel-wise approaches showed a significant correlation and no significant difference but, in presence of significant iron load, the region-based approach resulted in significantly higher T2* values.