Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Bacterial adhesion characteristics on implant materials for intervertebral cages: titanium or PEEK for spinal infections?
by
Weisselberg Samira
, Stangenberg, Martin
, Westphal Manfred
, Simon, von Kroge
, Eicker, Sven Oliver
, Dreimann, Marc
, Krätzig Theresa
, Mende, Klaus Christian
, Mohme Malte
in
Bacteria
/ Biofilms
/ Drug resistance
/ Electron microscopy
/ Microscopy
/ Surgical mesh
/ Titanium
2021
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Bacterial adhesion characteristics on implant materials for intervertebral cages: titanium or PEEK for spinal infections?
by
Weisselberg Samira
, Stangenberg, Martin
, Westphal Manfred
, Simon, von Kroge
, Eicker, Sven Oliver
, Dreimann, Marc
, Krätzig Theresa
, Mende, Klaus Christian
, Mohme Malte
in
Bacteria
/ Biofilms
/ Drug resistance
/ Electron microscopy
/ Microscopy
/ Surgical mesh
/ Titanium
2021
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Bacterial adhesion characteristics on implant materials for intervertebral cages: titanium or PEEK for spinal infections?
by
Weisselberg Samira
, Stangenberg, Martin
, Westphal Manfred
, Simon, von Kroge
, Eicker, Sven Oliver
, Dreimann, Marc
, Krätzig Theresa
, Mende, Klaus Christian
, Mohme Malte
in
Bacteria
/ Biofilms
/ Drug resistance
/ Electron microscopy
/ Microscopy
/ Surgical mesh
/ Titanium
2021
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Bacterial adhesion characteristics on implant materials for intervertebral cages: titanium or PEEK for spinal infections?
Journal Article
Bacterial adhesion characteristics on implant materials for intervertebral cages: titanium or PEEK for spinal infections?
2021
Request Book From Autostore
and Choose the Collection Method
Overview
PurposeSurgical intervention with intercorporal stabilisation in spinal infections is increasingly needed. Our aim was to compare titanium and polyetheretherketon (PEEK) cages according to their adhesion characteristics of different bacteria species in vitro. MethodsPlates made from PEEK, polished titanium (Ti), two-surface-titanium (TiMe) (n = 2–3) and original PEEK and porous trabecular structured titanium (TiLi) interbody cages (n = 4) were inoculated in different bacterial solutions, S.aureus (MSSA, MRSA), S.epidermidis and E.coli. Growth characteristics were analysed. Biofilms and bacteria were visualised using confocal- and electron microscopy.ResultsQuantitative adherence of MSSA, MRSA, S.epidermidis and E.coli to Ti, TiMe and PEEK plates were different, with polished titanium being mainly advantageous over PEEK and TiMe with significantly less counts of colony forming units (CFU) for MRSA after 56 h compared to TiMe and at 72 h compared to PEEK (p = 0.04 and p = 0.005). For MSSA, more adherent bacteria were detected on PEEK than on TiMe at 32 h (p = 0.02). For PEEK and TiLi cages, significant differences were found after 8 and 72 h for S.epidermidis (p = 0.02 and p = 0.008) and after 72 h for MSSA (p = 0.002) with higher bacterial counts on PEEK, whereas E.coli showed more CFU on TiLi than PEEK (p = 0.05). Electron microscopy demonstrated enhanced adhesion in transition areas.ConclusionFor S.epidermidis, MSSA and MRSA PEEK cages showed a higher adherence in terms of CFU count, whereas for E.coli PEEK seemed to be advantageous. Electron microscopic visualisation shows that bacteria did not adhere at the titanium mesh structure, but at the border zones of polished material to rougher parts.
Publisher
Springer Nature B.V
Subject
MBRLCatalogueRelatedBooks
Related Items
Related Items
We currently cannot retrieve any items related to this title. Kindly check back at a later time.
This website uses cookies to ensure you get the best experience on our website.