Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Four-Dimensional Flow Magnetic Resonance Imaging for Assessment of Velocity Magnitudes and Flow Patterns in The Human Carotid Artery Bifurcation: Comparison with Computational Fluid Dynamics
by
Chung, Gyung Ho
, Ngo, Minh Tri
, Jung, Jinmu
, Lee, Dong Hwan
, Kim, Chul In
, Kwak, Hyo Sung
in
Boundary conditions
/ Cardiovascular disease
/ Carotid arteries
/ Computer simulation
/ Flow velocity
/ Fluid dynamics
/ Geometry
/ Hemodynamics
/ Magnetic resonance imaging
/ Shear stress
/ Software
/ Veins & arteries
2019
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Four-Dimensional Flow Magnetic Resonance Imaging for Assessment of Velocity Magnitudes and Flow Patterns in The Human Carotid Artery Bifurcation: Comparison with Computational Fluid Dynamics
by
Chung, Gyung Ho
, Ngo, Minh Tri
, Jung, Jinmu
, Lee, Dong Hwan
, Kim, Chul In
, Kwak, Hyo Sung
in
Boundary conditions
/ Cardiovascular disease
/ Carotid arteries
/ Computer simulation
/ Flow velocity
/ Fluid dynamics
/ Geometry
/ Hemodynamics
/ Magnetic resonance imaging
/ Shear stress
/ Software
/ Veins & arteries
2019
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Four-Dimensional Flow Magnetic Resonance Imaging for Assessment of Velocity Magnitudes and Flow Patterns in The Human Carotid Artery Bifurcation: Comparison with Computational Fluid Dynamics
by
Chung, Gyung Ho
, Ngo, Minh Tri
, Jung, Jinmu
, Lee, Dong Hwan
, Kim, Chul In
, Kwak, Hyo Sung
in
Boundary conditions
/ Cardiovascular disease
/ Carotid arteries
/ Computer simulation
/ Flow velocity
/ Fluid dynamics
/ Geometry
/ Hemodynamics
/ Magnetic resonance imaging
/ Shear stress
/ Software
/ Veins & arteries
2019
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Four-Dimensional Flow Magnetic Resonance Imaging for Assessment of Velocity Magnitudes and Flow Patterns in The Human Carotid Artery Bifurcation: Comparison with Computational Fluid Dynamics
Journal Article
Four-Dimensional Flow Magnetic Resonance Imaging for Assessment of Velocity Magnitudes and Flow Patterns in The Human Carotid Artery Bifurcation: Comparison with Computational Fluid Dynamics
2019
Request Book From Autostore
and Choose the Collection Method
Overview
Purpose: Knowledge of the hemodynamics in the vascular system is important to understand and treat vascular pathology. The present study aimed to evaluate the hemodynamics in the human carotid artery bifurcation measured by four-dimensional (4D) flow magnetic resonance imaging (MRI) as compared to computational fluid dynamics (CFD). Methods: This protocol used MRI data of 12 healthy volunteers for the 3D vascular models and 4D flow MRI measurements for the boundary conditions in CFD simulation. We compared the velocities measured at the carotid bifurcation and the 3D velocity streamlines of the carotid arteries obtained by these two methods. Results: There was a good agreement for both maximum and minimum velocity values between the 2 methods for velocity magnitude at the bifurcation plane. However, on the 3D blood flow visualization, secondary flows, and recirculation regions are of poorer quality when visualized through the 4D flow MRI. Conclusion: 4D flow MRI and CFD show reasonable agreement in demonstrated velocity magnitudes at the carotid artery bifurcation. However, the visualization of blood flow at the recirculation regions and the assessment of secondary flow characteristics should be enhanced for the use of 4D flow MRI in clinical situations.
Publisher
MDPI AG,MDPI
This website uses cookies to ensure you get the best experience on our website.