MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Inducing granulation within a full-scale activated sludge system to improve settling
Inducing granulation within a full-scale activated sludge system to improve settling
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Inducing granulation within a full-scale activated sludge system to improve settling
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Inducing granulation within a full-scale activated sludge system to improve settling
Inducing granulation within a full-scale activated sludge system to improve settling

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Inducing granulation within a full-scale activated sludge system to improve settling
Inducing granulation within a full-scale activated sludge system to improve settling
Journal Article

Inducing granulation within a full-scale activated sludge system to improve settling

2021
Request Book From Autostore and Choose the Collection Method
Overview
Most cold-climate biological nutrient removal facilities experience poor settling mixed liquor during winter, resulting in treatment capacity throughput limitations. The Metro Wastewater Reclamation District in Denver, Colorado, operated two full-scale secondary treatment trains to compare the existing biological nutrient removal configuration (Control) to one that was modified to operate with an anaerobic selector and with hydrocyclone selective wasting (Test) to induce granulation. Results from this evaluation showed that the Test achieved significantly better settling behaviour than the Control. The difference in the mean diluted SVI30 between the Test and Control were statistically significant (P < 0.05), with values of 77 ± 17 and 135 ± 25 mL/g observed for the Test and Control respectively. These settling results were accompanied by differences in the particle size distribution, with notably higher settling velocities commensurate with increasing particle size. The degree of granulation observed in the Test train was between 32 and 56% of the mass greater than ≥250 μm in particle size whereas 16% of the mixed liquor in the Control was ≥250 μm over the entire study period. The improved settling behaviour of the Test configuration may translate into an increase of secondary treatment capacity during winter by 32%.