Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Deep sedation versus minimal sedation during endobronchial ultrasound transbronchial needle aspiration
by
Conte, Sergio C
, Confalonieri, Marco
, Brizi, Beatrice
, Spagnol, Giulia
in
Accuracy
/ Anesthesia
/ Patient satisfaction
/ Ultrasonic imaging
2018
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Deep sedation versus minimal sedation during endobronchial ultrasound transbronchial needle aspiration
by
Conte, Sergio C
, Confalonieri, Marco
, Brizi, Beatrice
, Spagnol, Giulia
in
Accuracy
/ Anesthesia
/ Patient satisfaction
/ Ultrasonic imaging
2018
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Deep sedation versus minimal sedation during endobronchial ultrasound transbronchial needle aspiration
Journal Article
Deep sedation versus minimal sedation during endobronchial ultrasound transbronchial needle aspiration
2018
Request Book From Autostore
and Choose the Collection Method
Overview
The sedation plays an important role in the endobronchial ultrasound transbronchial needle aspiration (EBUS-TB) procedure. The sedation can be Minimal (anxiolysis), Moderate (conscious sedation) or Deep. The ACCP guidelines suggest that moderate or deep sedation (DS) is an acceptable approach. In fact, several studies compare moderate versusdeep sedation, but no study has been carried out to compare deep sedation versusminimal. We carried out a retrospective study to compare the Deep versusMinimal sedation (MiS) in patients undergoing EBUS-TB. The primary end point was the diagnostic accuracy. The secondary end points were adequacy and sensitivity. We evaluated the LN size sampling, procedural time, complications and patient tolerance. Thirty-six patients underwent EBUS-TB, 16 under DS and 20 under MiS. The overall diagnostic accuracy for correct diagnosis was 92.9% in DS group and 94.1% in MiS group (p=0.554). Sample adequacy,defined as the percentage of patients with a specific diagnosis by EBUS-TB, was 87.5% (14 of 16) and 85% (17 of 20) for the DS group and MiS group, respectively, (p=0.788); the sensitivity was 92.9% in the DS group (95% CI, 73-100%) and 92.9% in the MiS group (95% CI, 77-100%) (p=0.463). There were no major complications in either group. Minor complications were 4 in MiS and 1 in DS (p=0.355). The patients in the MiS group recalled the procedure more often compared to the other group (p=0.041). The majority of the patients would agree to undergo the same procedure again in the future in both groups (p=0.766). In our experience EBUS-TB performed under MiS has comparable accuracy, adequacy, sensitivity, complications and patient satisfaction to DS, even if the sample was small. Future prospective multicenter studies are needed to confirm our results.
Publisher
PAGEPress Publications
Subject
This website uses cookies to ensure you get the best experience on our website.