Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Rail or roll: a new, convenient and safe way to position self-gripping meshes in open inguinal hernia repair
by
Köhler, G.
, Jäger, T.
, Mayer, F.
, Buchner, S.
, Lechner, M. N.
, Öfner, D.
in
Abdominal Surgery
/ Aged
/ Feasibility Studies
/ Female
/ Hernia, Inguinal - surgery
/ Herniorrhaphy - methods
/ Humans
/ Male
/ Medicine
/ Medicine & Public Health
/ Middle Aged
/ Original Article
/ Surgical Mesh
2016
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Rail or roll: a new, convenient and safe way to position self-gripping meshes in open inguinal hernia repair
by
Köhler, G.
, Jäger, T.
, Mayer, F.
, Buchner, S.
, Lechner, M. N.
, Öfner, D.
in
Abdominal Surgery
/ Aged
/ Feasibility Studies
/ Female
/ Hernia, Inguinal - surgery
/ Herniorrhaphy - methods
/ Humans
/ Male
/ Medicine
/ Medicine & Public Health
/ Middle Aged
/ Original Article
/ Surgical Mesh
2016
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Rail or roll: a new, convenient and safe way to position self-gripping meshes in open inguinal hernia repair
by
Köhler, G.
, Jäger, T.
, Mayer, F.
, Buchner, S.
, Lechner, M. N.
, Öfner, D.
in
Abdominal Surgery
/ Aged
/ Feasibility Studies
/ Female
/ Hernia, Inguinal - surgery
/ Herniorrhaphy - methods
/ Humans
/ Male
/ Medicine
/ Medicine & Public Health
/ Middle Aged
/ Original Article
/ Surgical Mesh
2016
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Rail or roll: a new, convenient and safe way to position self-gripping meshes in open inguinal hernia repair
Journal Article
Rail or roll: a new, convenient and safe way to position self-gripping meshes in open inguinal hernia repair
2016
Request Book From Autostore
and Choose the Collection Method
Overview
Purpose
In open inguinal hernia repair self-gripping meshes are currently commonly employed. Assumed benefits are saving of time, ease of handling and omission of fixation. Self-gripping meshes are, however, not as easy to handle and position as commonly stated. We describe a newly developed way of intra-operative mesh preparation and implantation and compare it to the conventional technique of insertion of self-gripping meshes.
Methods
A two-armed, randomized trial with 64 patients was performed. For implantation of the self-gripping, light weight and partially absorbable mesh we used either a newly described rolling technique (group 1:
n
= 32) or the conventional way of insertion (group 2:
n
= 32). Primary endpoints of the study were feasibility with regard to actual implantation time and surgeons’ satisfaction with the methods. Secondary endpoints were total operating time, length of hospital stay, postoperative pain, duration of pain medication intake and postoperative morbidity. In addition all patients were prospectively followed up according to the Hernia Med® registry’s standards.
Results
Implantation time (seconds) 140 ± 74 vs. 187 ± 84,
p
= 0.008, duration of pain medication intake (days) 3.6 ± 2.8 vs. 4.8 ± 2.6;
p
= 0.046 and postoperative morbidity 2 (6%) vs. 8 (25%) was significantly beneficial in group 1 (rolling technique) compared to group 2 (conventional method). Blinded questionnaire revealed that rolling the mesh is generally easier with less repositioning maneuvers than conventional placement. Neither overall procedure time, length of stay nor postoperative pain scores differed significantly between groups.
Conclusion
The newly introduced rolling technique for the actual placement of self-gripping meshes in open inguinal hernia repair is technically less demanding and therefore significantly faster when compared to the conventional way of insertion of the same product. In addition the rolling technique has shown to be safe for the patients and to also provide higher surgeons’ satisfaction.
Publisher
Springer Paris,Springer Nature B.V
This website uses cookies to ensure you get the best experience on our website.