Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Clinical experience with contact-force and flexible-tip ablation catheter designs
by
Hamm, C. W.
, Neumann, T.
, Deubner, N.
, Akkaya, E.
, Berkowitsch, A.
, Greiss, H.
, Zaltsberg, S.
, Kuniss, M.
in
Aged
/ Atrial Fibrillation - diagnosis
/ Atrial Fibrillation - epidemiology
/ Atrial Fibrillation - surgery
/ Cardiology
/ Catheter Ablation - instrumentation
/ Catheter Ablation - methods
/ Catheter Ablation - statistics & numerical data
/ Disease-Free Survival
/ Elastic Modulus
/ Equipment Design
/ Equipment Failure Analysis
/ Female
/ Humans
/ Male
/ Medicine
/ Medicine & Public Health
/ Middle Aged
/ Monitoring, Intraoperative - instrumentation
/ Monitoring, Intraoperative - methods
/ Monitoring, Intraoperative - statistics & numerical data
/ Prevalence
/ Recurrence
/ Reproducibility of Results
/ Sensitivity and Specificity
/ Stress, Mechanical
/ Treatment Outcome
2016
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Clinical experience with contact-force and flexible-tip ablation catheter designs
by
Hamm, C. W.
, Neumann, T.
, Deubner, N.
, Akkaya, E.
, Berkowitsch, A.
, Greiss, H.
, Zaltsberg, S.
, Kuniss, M.
in
Aged
/ Atrial Fibrillation - diagnosis
/ Atrial Fibrillation - epidemiology
/ Atrial Fibrillation - surgery
/ Cardiology
/ Catheter Ablation - instrumentation
/ Catheter Ablation - methods
/ Catheter Ablation - statistics & numerical data
/ Disease-Free Survival
/ Elastic Modulus
/ Equipment Design
/ Equipment Failure Analysis
/ Female
/ Humans
/ Male
/ Medicine
/ Medicine & Public Health
/ Middle Aged
/ Monitoring, Intraoperative - instrumentation
/ Monitoring, Intraoperative - methods
/ Monitoring, Intraoperative - statistics & numerical data
/ Prevalence
/ Recurrence
/ Reproducibility of Results
/ Sensitivity and Specificity
/ Stress, Mechanical
/ Treatment Outcome
2016
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Clinical experience with contact-force and flexible-tip ablation catheter designs
by
Hamm, C. W.
, Neumann, T.
, Deubner, N.
, Akkaya, E.
, Berkowitsch, A.
, Greiss, H.
, Zaltsberg, S.
, Kuniss, M.
in
Aged
/ Atrial Fibrillation - diagnosis
/ Atrial Fibrillation - epidemiology
/ Atrial Fibrillation - surgery
/ Cardiology
/ Catheter Ablation - instrumentation
/ Catheter Ablation - methods
/ Catheter Ablation - statistics & numerical data
/ Disease-Free Survival
/ Elastic Modulus
/ Equipment Design
/ Equipment Failure Analysis
/ Female
/ Humans
/ Male
/ Medicine
/ Medicine & Public Health
/ Middle Aged
/ Monitoring, Intraoperative - instrumentation
/ Monitoring, Intraoperative - methods
/ Monitoring, Intraoperative - statistics & numerical data
/ Prevalence
/ Recurrence
/ Reproducibility of Results
/ Sensitivity and Specificity
/ Stress, Mechanical
/ Treatment Outcome
2016
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Clinical experience with contact-force and flexible-tip ablation catheter designs
Journal Article
Clinical experience with contact-force and flexible-tip ablation catheter designs
2016
Request Book From Autostore
and Choose the Collection Method
Overview
Purpose
Lesion formation is a critical determinant of technical and clinical success of pulmonary vein isolation. Different catheter designs aim to enhance tissue contact during ablation to enable optimized lesion formation. We analyzed procedural characteristics and predictors of clinical success in patients ablated with three different contemporary ablation catheters.
Methods
Two hundred sixty-eight sequentially included patients receiving pulmonary vein isolation (PVI) with conventional (
n
= 122), contact-force (
n
= 96) and flexible-tip (
n
= 60) catheters were followed for a median of 14.1 months with 7d-Holter-monitoring and TTE at 3, 6, 12, and 24 months. Baseline characteristics and follow-up times were homogeneous across all groups.
Results
Multivariable Cox proportional hazard regression for arrhythmia recurrence demonstrated a favorable hazard ratio for contact-force and flexible-tip catheters vs. conventional open irrigation catheters. Procedure time and fluoroscopy time were shorter for contact-force and flexible-tip catheters versus conventional catheters, but equal between. Linear lesions were applied in 58 % of contact-force and 66 % of flexible-tip cases, and CFAEs were targeted in 26 % of either.
Conclusions
Our non-randomized prospectively collected data do not show a difference in observed procedure characteristics and in clinical outcome for flexible-tip versus contact-force catheter designs, while both display improved performance against conventional open irrigated-tip catheters. Linear lesions and CFAEs ablation were not associated with improved arrhythmia-free survival.
Publisher
Springer US,Springer Nature B.V
Subject
/ Atrial Fibrillation - diagnosis
/ Atrial Fibrillation - epidemiology
/ Atrial Fibrillation - surgery
/ Catheter Ablation - instrumentation
/ Catheter Ablation - statistics & numerical data
/ Female
/ Humans
/ Male
/ Medicine
/ Monitoring, Intraoperative - instrumentation
/ Monitoring, Intraoperative - methods
This website uses cookies to ensure you get the best experience on our website.