MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Ventilator-associated nosocomial pneumonia in intensive care units in Malaysia
Ventilator-associated nosocomial pneumonia in intensive care units in Malaysia
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Ventilator-associated nosocomial pneumonia in intensive care units in Malaysia
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Ventilator-associated nosocomial pneumonia in intensive care units in Malaysia
Ventilator-associated nosocomial pneumonia in intensive care units in Malaysia

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Ventilator-associated nosocomial pneumonia in intensive care units in Malaysia
Ventilator-associated nosocomial pneumonia in intensive care units in Malaysia
Journal Article

Ventilator-associated nosocomial pneumonia in intensive care units in Malaysia

2009
Request Book From Autostore and Choose the Collection Method
Overview
Background: The outcome indicator of nosocomial infection (NI) in the intensive care unit (ICU) is used to benchmark the quality of patient care in Malaysia. We conducted a three-year prospective study on the incidences of ventilator-associated pneumonia (VAP), risk factors, and patterns of the microorganisms isolated in three ICUs. Methodology: A follow-up in prospective cohort surveillance was conducted on patients admitted to an adult medical-surgical ICU of a university hospital and two governmental hospitals in Malaysia from October 2003 to December 2006. VAP was detected using CDC criteria which included clinical manifestation and confirmed endotracheal secretion culture results. Results: In total, 215 patients (2,306 patient-days) were enrolled into the study. The incidence of ICU-acquired device-related NI was 29.3 % (n = 63). The device-related VAP infection rate was 27.0 % (n = 58), with a mechanical ventilator utilization rate of 88.7%. The death rate due to all ICU-acquired NI including sepsis was 6.5%. The most common causative pathogen was Klebsiella pneumoniae (n = 27). Multivariate analysis using Cox regression showed that the risk factors identified were aspiration pneumonia (HR = 4.09; 95% CI = 1.24, 13.51; P = 0.021), cancer (HR = 2.51; 95% CI = 1.27, 4.97; P = 0.008), leucocytosis (HR=3.43; 95% CI= 1.60, 7.37; P=0.002) and duration of mechanical ventilation (HR=1.04; 95% CI = 1.00, 1.08; P = 0.030).  Age, gender and race were not identified as risk factors in the multivariable analysis performed. Conclusion: The incidence of VAP was comparable to that found in the National Nosocomial Infection Surveillance (NNIS) System report of June 1998. The incidence of VAP was considered high for the three hospitals studied.