Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Long‐term performance monitoring of a‐Si 1200 electronic portal imaging device for dosimetric applications
by
Rivest, Ryan
, Kutuzov, Ivan
, McCurdy, Boyd
, VanUytven, Eric
in
Calibration
/ Datasets
/ Dosimetry
/ Electrical Equipment and Supplies
/ EPID
/ EPID dosimetry
/ EPID response stability
/ Humans
/ linac output
/ linac QA
/ machine QA
/ Particle Accelerators - instrumentation
/ Radiation Oncology Physics
/ Radiation therapy
/ Radiometry - instrumentation
/ Radiometry - methods
/ Radiotherapy
/ Radiotherapy Dosage
/ Radiotherapy Planning, Computer-Assisted - methods
/ Radiotherapy, Intensity-Modulated - instrumentation
/ Radiotherapy, Intensity-Modulated - methods
/ Reproducibility
/ Sensors
/ Standard deviation
/ Trends
2025
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Long‐term performance monitoring of a‐Si 1200 electronic portal imaging device for dosimetric applications
by
Rivest, Ryan
, Kutuzov, Ivan
, McCurdy, Boyd
, VanUytven, Eric
in
Calibration
/ Datasets
/ Dosimetry
/ Electrical Equipment and Supplies
/ EPID
/ EPID dosimetry
/ EPID response stability
/ Humans
/ linac output
/ linac QA
/ machine QA
/ Particle Accelerators - instrumentation
/ Radiation Oncology Physics
/ Radiation therapy
/ Radiometry - instrumentation
/ Radiometry - methods
/ Radiotherapy
/ Radiotherapy Dosage
/ Radiotherapy Planning, Computer-Assisted - methods
/ Radiotherapy, Intensity-Modulated - instrumentation
/ Radiotherapy, Intensity-Modulated - methods
/ Reproducibility
/ Sensors
/ Standard deviation
/ Trends
2025
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Long‐term performance monitoring of a‐Si 1200 electronic portal imaging device for dosimetric applications
by
Rivest, Ryan
, Kutuzov, Ivan
, McCurdy, Boyd
, VanUytven, Eric
in
Calibration
/ Datasets
/ Dosimetry
/ Electrical Equipment and Supplies
/ EPID
/ EPID dosimetry
/ EPID response stability
/ Humans
/ linac output
/ linac QA
/ machine QA
/ Particle Accelerators - instrumentation
/ Radiation Oncology Physics
/ Radiation therapy
/ Radiometry - instrumentation
/ Radiometry - methods
/ Radiotherapy
/ Radiotherapy Dosage
/ Radiotherapy Planning, Computer-Assisted - methods
/ Radiotherapy, Intensity-Modulated - instrumentation
/ Radiotherapy, Intensity-Modulated - methods
/ Reproducibility
/ Sensors
/ Standard deviation
/ Trends
2025
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Long‐term performance monitoring of a‐Si 1200 electronic portal imaging device for dosimetric applications
Journal Article
Long‐term performance monitoring of a‐Si 1200 electronic portal imaging device for dosimetric applications
2025
Request Book From Autostore
and Choose the Collection Method
Overview
Purpose Recently, dosimetri applications of the electronic portal imaging device (EPID) in radiotherapy have gained popularity. Confidence in the robust and reliable dosimetric performance of EPID detectors is essential for their clinical use. This study aimed to evaluate the dosimetric performance of the a‐Si 1200 EPID and assess the long‐term stability of its response. Methods Weekly measurements were performed on two clinically used TrueBeam linear accelerators (linacs) equipped with a‐Si 1200 EPID detectors over a 2‐year period. They included dark and flood calibration fields, and EPID response to an open field corrected for the long‐term machine output drift measured with the secondary absolute dosimeters: an ion chamber and an ion chamber array. All measurements were performed using five photon beam energies and two imaging modes: continuous and dosimetry. The measurements were analyzed for constancy and the presence of long‐term trends. Comparisons were made between the two linacs for each beam energy. Pixel sensitivity matrices (PSM) were determined semi‐annually and analyzed for long‐term constancy for both treatment machines. Results The long‐term variation of the dark and flood field signals, integrated across the EPID plane, over the entire observation period did not exceed 0.17% and 0.79%, respectively. The output‐corrected EPID response showed long‐term variation from 0.28% to 0.36%, depending on beam energy, while the short‐term variation was 0.04%–0.07% for EPID and 0.02%–0.06% for secondary dosimeters. The long‐term variation of secondary dosimeters was 0.2%–0.3%. PSMs were found to be stable to within 1% for 97.8% of pixels and 2% for 100% of pixels. Conclusion Techniques to monitor and assess the long‐term performance of the a‐Si 1200 EPID as a dosimeter were developed and implemented using two TrueBeam linacs. The long‐term variation of the EPID response was within clinical tolerance indicated in AAPM TG‐142 report, and the detector was shown to be stable and reproducible for routine clinical dosimetry.
Publisher
John Wiley & Sons, Inc,John Wiley and Sons Inc
Subject
/ Datasets
/ Electrical Equipment and Supplies
/ EPID
/ Humans
/ linac QA
/ Particle Accelerators - instrumentation
/ Radiometry - instrumentation
/ Radiotherapy Planning, Computer-Assisted - methods
/ Radiotherapy, Intensity-Modulated - instrumentation
/ Radiotherapy, Intensity-Modulated - methods
/ Sensors
/ Trends
MBRLCatalogueRelatedBooks
Related Items
Related Items
We currently cannot retrieve any items related to this title. Kindly check back at a later time.
This website uses cookies to ensure you get the best experience on our website.