MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Large False Lumen Area Is a Predictor of Failed False Lumen Volume Reduction After Stent-Graft Repair in Type B Aortic Dissection
Large False Lumen Area Is a Predictor of Failed False Lumen Volume Reduction After Stent-Graft Repair in Type B Aortic Dissection
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Large False Lumen Area Is a Predictor of Failed False Lumen Volume Reduction After Stent-Graft Repair in Type B Aortic Dissection
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Large False Lumen Area Is a Predictor of Failed False Lumen Volume Reduction After Stent-Graft Repair in Type B Aortic Dissection
Large False Lumen Area Is a Predictor of Failed False Lumen Volume Reduction After Stent-Graft Repair in Type B Aortic Dissection

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Large False Lumen Area Is a Predictor of Failed False Lumen Volume Reduction After Stent-Graft Repair in Type B Aortic Dissection
Large False Lumen Area Is a Predictor of Failed False Lumen Volume Reduction After Stent-Graft Repair in Type B Aortic Dissection
Journal Article

Large False Lumen Area Is a Predictor of Failed False Lumen Volume Reduction After Stent-Graft Repair in Type B Aortic Dissection

2014
Request Book From Autostore and Choose the Collection Method
Overview
Purpose To investigate the predictors of failed false lumen (FL) volume reduction at 12 months after stent-graft implantation in patients with type B aortic dissection. Methods The retrospective analysis comprised 38 patients (25 men; mean age 60±12 years) with double-barrel type B aortic dissection (9 acute) treated with thoracic endovascular aortic repair (TEVAR) and evaluated with serial computed tomography (CT) scans up to 12 months. Aortic volume changes were determined. Based on FL volume change at 1 year after stent-graft implantation, patients were dichotomized according to the presence or absence of FL volume reduction. Clinical and CT variables were compared between groups to determine risk factors of failed FL volume reduction. A major adverse event (MAE) was defined as death or reintervention. Results Patients were followed for 4.2±2.8 years. FL volume reduction (+FLVR) occurred in 27 (71%) patients, whereas 11 (29%) patients had no FL volume reduction (-FLVR). The MAE-free survival rate was significantly higher in the +FLVR patients than in the -FLVR group (88.9% vs. 27.3%, respectively; p=0.001). Chronicity of dissection, location of tear site, or the maximum total aortic lumen area was not associated with failure to achieve FL volume reduction. However, the maximum preprocedure FL area was significantly lower in the +FLVR group than in the -FLVR group (12.6±6.6 vs. 21.0±11.4 cm2, respectively; p=0.041) and was an independent predictor for failed FL volume reduction (odds ratio 1.3, 95% confidence interval 1.02 to 1.70, p=0.031). Conclusion Failed FL volume reduction after TEVAR was associated with a significantly increased rate of mortality or reintervention during follow-up. A larger preprocedure maximum FL area was a predictor of failed FL volume reduction after TEVAR in type B dissection.