MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Dose reduction in half-time myocardial perfusion SPECT-CT with multifocal collimation
Dose reduction in half-time myocardial perfusion SPECT-CT with multifocal collimation
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Dose reduction in half-time myocardial perfusion SPECT-CT with multifocal collimation
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Dose reduction in half-time myocardial perfusion SPECT-CT with multifocal collimation
Dose reduction in half-time myocardial perfusion SPECT-CT with multifocal collimation

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Dose reduction in half-time myocardial perfusion SPECT-CT with multifocal collimation
Dose reduction in half-time myocardial perfusion SPECT-CT with multifocal collimation
Journal Article

Dose reduction in half-time myocardial perfusion SPECT-CT with multifocal collimation

2016
Request Book From Autostore and Choose the Collection Method
Overview
Recent technological advances in myocardial perfusion imaging may warrant the use of lower injected activity. We evaluated whether quantitative measures of stress myocardial perfusion defects using Tc-99m sestamibi and low-energy high-resolution (LEHR) collimators are equivalent to lower dose SPECT-CT with cardiac multifocal collimators and software (IQ·SPECT). 93 patients underwent one-day rest-stress gated SPECT-CT. Following conventional rest imaging, 925-1100 MBq (25-30 mCi) of Tc-99m sestamibi was injected during stress testing. Stress SPECT-CT images were acquired two ways: with LEHR (13 minutes) and IQ·SPECT (7 minutes). Low-dose IQ·SPECT stress was simulated by subsampling the full-dose data to half-, quarter-, and eighth-count levels. Abnormalities were quantified using the total perfusion deficit (TPD) score and dose-specific databases. The mean ± SD of the differences between LEHR and IQ·SPECT TPD scores were −1.01 ± 5.36%, −0.10 ± 5.81%, 1.78 ± 4.81%, and 1.75 ± 6.05% at full, half, quarter, and eighth doses, respectively. Differences were statistically significant for quarter and eighth doses. Correlation between LEHR and IQ·SPECT was excellent at all doses (R ≥ 0.93). Bland-Altman plots demonstrated minimal bias. With IQ·SPECT, quantitative stress SPECT-CT imaging is possible with half of the standard injected activity in half the time. Los recientes avances tecnológicos en la imagen de perfusión miocárdica (MPI) pueden justificar el uso de una menor actividad inyectada. Nosotros evaluamos si las mediciones cuantitativas de los defectos de perfusión en estrés usando Tc-99m sestamibi y colimadores de baja energía y alta resolución (LEHR) son equivalentes a dosis menores en SPECT-CT con colimadores multifocales y programa de procesamiento cardiacos (IQ·SPECT). 93 pacientes sometidos a gated SPECT-CT reposo – estrés en un solo día. Después de la imagen convencional de reposo, se inyectaron 925-1100 MBq (25-30 mCi) de Tc-99m sestamibi durante la prueba de estrés. Las imágenes de estrés con SPECT-CT se adquirieron de dos formas: con LEHR (13 min) y con IQ·SPECT (7 min). La dosis baja con IQ·SPECT fue simulada haciendo un submuestreo de los datos de la dosis completa a niveles de la mitad, la cuarta y la octava parte de las cuentas. Las anormalidades se cuantificaron usando el déficit total de perfusión (TPD) y bases de datos específicas por dosis. Las medias ± DE de las diferencias de los valores de TPD entre LEHR y IQ·SPECT fueron −1.01 ± 5.36%, −0.10 ± 5.81%, 1.78 ± 4.81% y 1.75 ± 6.05% a dosis completa, media, cuarta y octava parte, respectivamente. Las diferencias fueron estadísticamente significativas para la cuarta y octava parte de dosis. La correlación entre LEHR con IQ·SPECT fue excelente con todas la dosis (R > 0.93). Las gráficas de Bland-Altman demostraron mínimo sesgo. Con IQ·SPECT, el estrés cuantitativo mediante la imagen de SPECT-CT es posible realizarlo con la mitad de la actividad estándar inyectada y en la mitad de tiempo. 最近心脏灌注显像(MPI)的技术进步使得在较低注射剂量的条件下MPI成像变得可行。 本文评估:采用Tc-99m甲氧基异丁基异腈显影剂和低能量高分辨率准直器定量测定负荷状态下心肌血流灌注缺损(LEHR方法), 是否等效于采用心脏多焦点准直器和软件进行的较低剂量SPECT-CT的测定结果 (IQ·SPECT方法)。 对入选的93个病人均采用负荷一日法/静息门控SPECT-CT 显影方案。 按照常规的方法进行静息图像的采集后, 在运动过程中静脉注射 925-1100 MBq(25-30mCi) 的 Tc-99m (甲氧基异丁基异腈)。 负荷SPECT-CT 图像是以两种方式采集:13分钟的LEHR和7分钟的 IQ·SPECT。 低剂量的负荷 IQ·SPECT是用全剂量样本的子样本来模拟, 分别是半剂量、 四分之一剂量和八分之一剂量。 用血流灌注缺损总积分(TPD)和剂量特征化数据库对心肌灌注异常进行定量。 分别采用LEHR与IQ·SPECT方法时, TPD积分差值的平均值±标准方差是 −1.01 ±5.36%, −0.10 ± 5.81%, 1.78 ± 4.81% 和 1.75 ± 6.05%, 分别对应于全剂量、半剂量、 四分之一剂量和八分之一剂量。在四分之一和八分之一剂量时采用LEHR与IQ·SPECT方法测定的TPD差值在统计学上有显著性差异。在所有剂量段时采用LEHR与 IQ·SPECT 方法测定的TPD都有很好的相关性(R ≥ 0.93)。Bland-Altman图形表明了最小偏差。 采用IQ·SPECT方法, 将图像采集时间和显影剂注射剂量都减半应用于负荷SPECT-CT成像是可行的。