MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Comparative evaluation of incidence of dentinal defects after root canal preparation using hand, rotary, and reciprocating files: An ex vivo study
Comparative evaluation of incidence of dentinal defects after root canal preparation using hand, rotary, and reciprocating files: An ex vivo study
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Comparative evaluation of incidence of dentinal defects after root canal preparation using hand, rotary, and reciprocating files: An ex vivo study
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Comparative evaluation of incidence of dentinal defects after root canal preparation using hand, rotary, and reciprocating files: An ex vivo study
Comparative evaluation of incidence of dentinal defects after root canal preparation using hand, rotary, and reciprocating files: An ex vivo study

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Comparative evaluation of incidence of dentinal defects after root canal preparation using hand, rotary, and reciprocating files: An ex vivo study
Comparative evaluation of incidence of dentinal defects after root canal preparation using hand, rotary, and reciprocating files: An ex vivo study
Journal Article

Comparative evaluation of incidence of dentinal defects after root canal preparation using hand, rotary, and reciprocating files: An ex vivo study

2022
Request Book From Autostore and Choose the Collection Method
Overview
Aim: To compare dentinal cracks incidences after root canal preparation using Hand K-files; Rotary files: Protaper NEXT (PTN), Hyflex Controlled Memory (CM); and Reciprocating files: Wave One and Wave One Gold files. Materials and Methods: Hundred extracted human mandibular first premolars with straight root canals were taken postextraction and were allocated randomly into five groups (n = 20 teeth per group). The canals were instrumented using Hand K-files, Protaper Next (PTN), Hyflex CM, Wave One, and Wave One Gold systems. Group 1-Control group comprised of canals prepared by Hand files. Further, the roots were sectioned at three levels: 3, 6, and 9 mm horizontally from the apex using a saw at a low-speed saw and under water cooling. These slices were examined under a stereomicroscope at 25× magnification and the presence of any dentinal cracks was noted. The frequency of cracks was presented in number and percentage. Intergroup comparison of crack frequency was performed using analysis of variance. Results: No cracks were observed in the control group. In all the other groups, dentinal cracks were observed. The rotary files PTN and Hyflex CM files produced significantly fewer dentinal cracks than the reciprocating Wave One and Wave One Gold files (P < 0.05). The reciprocating files significantly produced more cracks apically than the rotary files (P < 0.05). Analyses were performed on SPSS software (windows version 22.0). Conclusion: Instrumentation with file systems can cause crack formation in the dentinal wall of the root canal. Determination of which files to choose for root canal preparation is technique sensitive and each instrument type has own benefits. However, care should be taken while biomechanical preparation to avoid dentinal cracks formation.
Publisher
Wolters Kluwer - Medknow Publications,Medknow Publications and Media Pvt. Ltd,Medknow Publications & Media Pvt. Ltd