MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Varying Effects of Corneal Thickness on Intraocular Pressure Measurements with Different Tonometers
Varying Effects of Corneal Thickness on Intraocular Pressure Measurements with Different Tonometers
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Varying Effects of Corneal Thickness on Intraocular Pressure Measurements with Different Tonometers
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Varying Effects of Corneal Thickness on Intraocular Pressure Measurements with Different Tonometers
Varying Effects of Corneal Thickness on Intraocular Pressure Measurements with Different Tonometers

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Varying Effects of Corneal Thickness on Intraocular Pressure Measurements with Different Tonometers
Varying Effects of Corneal Thickness on Intraocular Pressure Measurements with Different Tonometers
Journal Article

Varying Effects of Corneal Thickness on Intraocular Pressure Measurements with Different Tonometers

2005
Request Book From Autostore and Choose the Collection Method
Overview
Aims To compare the intraocular pressure (IOP) measurements using the Goldmann applanation tonometer (GAT), noncontact tonometer (NCT), and ocular blood flow tonometer (OBFT), and to evaluate the effects of varying central corneal thickness (CCT) on the readings. Methods Ultrasound pachymetry and tonometry were performed on 170 eyes. Using the corrected GAT values that took CCT into account as the standard, we calculated the NCT and OBFT measurement errors related to the CCT variable by a linear regression model. Group comparisons were performed with the χ 2 test and one-way ANOVA test. The correlation between the various tonometer measurements was analysed by Pearson's correlation method. Results Both the NCT ( r =0.872, P <0.001) and OBFT measurements ( r =0.861, P <0.001) were highly correlated with the GAT measurements. IOP measurements using the three tonometers were all correlated with CCT (all P <0.001), with the NCT measurements showing the greatest regression coefficient ( β =0.063, r =0.650) and the GAT measurements the least ( β =0.037, r =0.496). A linear regression model indicated that a 10 μ m change in CCT resulted in a NCT measurement deviation of 0.47–0.98 mmHg and an OBFT measurement deviation of 0.29–0.81 mmHg. Conclusion Pressure readings with the GAT, NCT, and OBFT are all affected by CCT, with the NCT being the one most affected and the GAT the least. Our findings suggest CCT an essential variable to consider in interpreting IOP readings, especially for the NCT measurements.