Load Frequency Control in Two-Area Multi-Source Power System Using Bald Eagle-Sparrow Search Optimization Tuned PID Controller
by
Kumar, C.
, Fayek, Hady H.
, Raj, T. Dharma
, Kotsampopoulos, Panos
in
Algorithms
/ Control systems
/ Controllers
/ Electric power production
/ Electric power systems
/ Foraging behavior
/ India
/ Investigations
/ ITAE
/ LFC
/ Mathematical optimization
/ multiple source power system
/ optimization
/ Optimization algorithms
/ PID controller
/ Power plants
/ Predation
2023
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Load Frequency Control in Two-Area Multi-Source Power System Using Bald Eagle-Sparrow Search Optimization Tuned PID Controller
by
Kumar, C.
, Fayek, Hady H.
, Raj, T. Dharma
, Kotsampopoulos, Panos
in
Algorithms
/ Control systems
/ Controllers
/ Electric power production
/ Electric power systems
/ Foraging behavior
/ India
/ Investigations
/ ITAE
/ LFC
/ Mathematical optimization
/ multiple source power system
/ optimization
/ Optimization algorithms
/ PID controller
/ Power plants
/ Predation
2023
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Load Frequency Control in Two-Area Multi-Source Power System Using Bald Eagle-Sparrow Search Optimization Tuned PID Controller
by
Kumar, C.
, Fayek, Hady H.
, Raj, T. Dharma
, Kotsampopoulos, Panos
in
Algorithms
/ Control systems
/ Controllers
/ Electric power production
/ Electric power systems
/ Foraging behavior
/ India
/ Investigations
/ ITAE
/ LFC
/ Mathematical optimization
/ multiple source power system
/ optimization
/ Optimization algorithms
/ PID controller
/ Power plants
/ Predation
2023
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Load Frequency Control in Two-Area Multi-Source Power System Using Bald Eagle-Sparrow Search Optimization Tuned PID Controller
Journal Article
Load Frequency Control in Two-Area Multi-Source Power System Using Bald Eagle-Sparrow Search Optimization Tuned PID Controller
2023
Request Book From Autostore
and Choose the Collection Method
Overview
For power system engineers, automated load frequency control (LFC) for multi-area power networks has proven a difficult problem. With the addition of numerous power generation sources, the complexity of these duties becomes even more difficult. The dynamic nature of linked power networks with varied generating sources, such as gas, thermal, and hydropower plants, is compared in this research. For the study to be more accurate, frequency and tie-line power measurements are used. For precise tuning of proportional-integral-derivative (PID) controller gains, the Bald Eagle Sparrow search optimization (BESSO) technique was used. The BESSO algorithm was created by combining the characteristics of sparrows and bald eagles. The performance of BESSO is determined by comparing its findings to those acquired using traditional approaches. In terms of Integral Time Absolute Error (ITAE), which is the most important criterion used to reduce system error, the findings presented in this study indicate the effectiveness of the BESSO-PID controller. Finally, sensitivity analysis and stability analysis proved the robustness of the developed controller. The settling times associated with the tie-line power flow, frequency variation in area-1, and frequency variation in area-2, respectively, were 10.4767 s, 8.5572 s, and 11.4364 s, which were all less than the traditional approaches. As a result, the suggested method outperformed the other strategies.