MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Digital pair-matching of iliac bones: pilot study on a three-dimensional approach with models acquired through stereophotogrammetry
Digital pair-matching of iliac bones: pilot study on a three-dimensional approach with models acquired through stereophotogrammetry
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Digital pair-matching of iliac bones: pilot study on a three-dimensional approach with models acquired through stereophotogrammetry
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Digital pair-matching of iliac bones: pilot study on a three-dimensional approach with models acquired through stereophotogrammetry
Digital pair-matching of iliac bones: pilot study on a three-dimensional approach with models acquired through stereophotogrammetry

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Digital pair-matching of iliac bones: pilot study on a three-dimensional approach with models acquired through stereophotogrammetry
Digital pair-matching of iliac bones: pilot study on a three-dimensional approach with models acquired through stereophotogrammetry
Journal Article

Digital pair-matching of iliac bones: pilot study on a three-dimensional approach with models acquired through stereophotogrammetry

2023
Request Book From Autostore and Choose the Collection Method
Overview
Three-dimensional (3D) pair-matching has brought about an innovative approach for the analysis of commingled skeletal remains, and it has been tested on bone models acquired through CT and laser scans. Here, 3D models of 40 innominate bones (20 left and 20 right) of 20 documented male individuals from a cemeterial skeletal collection were acquired through a stereophotogrammetric device (VECTRA M3, Canfield Scientific, Inc.). The ventral iliac surface was chosen as the anatomical region of interest (ROI) for the analysis. Each left ROI was mirrored and superimposed on the matching right ROI (contralateral element from the same individual) and mismatching ROIs (contralateral elements from different individuals). The point-to-point distance between models was calculated through the Vectra Analysis Module (VAM) software and the root mean square (RMS) point-to-point distance value was used to evaluate the sorting performance of the method, in terms of sensitivity and specificity rates. Differences in RMS between matches and mismatches were investigated through a Student’s t test (p < 0.05). The state of preservation of the remains was assessed following an index of anatomical completeness and differences in RMS distances of true matches according to different anatomical completeness were assessed through the Mann–Whitney test (p < 0.05). RMS point-to-point distances of matches and mismatches were significantly different (p < 0.01), being the matches lower than mismatches. The RMS threshold of 2.9 mm identified all the true pairs; the test was 100% sensitive and 51% specific. The RMS of matches with a better state of preservation are significantly lower than the less preserved matches (p < 0.05). In general, a low RMS distance value may indicate a true match, being it to be further verified. The 3D approach for sorting innominate bones provides a valid screening test that could complete subjective and osteometric methods with numerical evidence of the match. Preliminary data suggest a possible relation between RMS distance values and taphonomic condition, which would benefit from further research.