Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Low rate of substantial loss of reduction immediately after hardware removal following acromioclavicular joint stabilization using a suspensory fixation system
by
Siebenlist, Sebastian
, Hinz, Maximilian
, Pogorzelski, Jonas
, Muench, Lukas N.
, Feucht, Matthias J.
, Rupp, Marco-Christopher
, Scheiderer, Bastian
, Kadantsev, Pavel M.
, Imhoff, Andreas B.
, Berthold, Daniel P.
in
Fixation
/ Hardware
/ Joint and ligament injuries
/ Medicine
/ Medicine & Public Health
/ Orthopedics
/ Patients
/ Risk analysis
/ Risk factors
/ Shoulder
/ Sports Medicine
/ Stabilization
/ Statistical analysis
/ Subgroups
/ Surgery
/ Sutures
2022
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Low rate of substantial loss of reduction immediately after hardware removal following acromioclavicular joint stabilization using a suspensory fixation system
by
Siebenlist, Sebastian
, Hinz, Maximilian
, Pogorzelski, Jonas
, Muench, Lukas N.
, Feucht, Matthias J.
, Rupp, Marco-Christopher
, Scheiderer, Bastian
, Kadantsev, Pavel M.
, Imhoff, Andreas B.
, Berthold, Daniel P.
in
Fixation
/ Hardware
/ Joint and ligament injuries
/ Medicine
/ Medicine & Public Health
/ Orthopedics
/ Patients
/ Risk analysis
/ Risk factors
/ Shoulder
/ Sports Medicine
/ Stabilization
/ Statistical analysis
/ Subgroups
/ Surgery
/ Sutures
2022
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Low rate of substantial loss of reduction immediately after hardware removal following acromioclavicular joint stabilization using a suspensory fixation system
by
Siebenlist, Sebastian
, Hinz, Maximilian
, Pogorzelski, Jonas
, Muench, Lukas N.
, Feucht, Matthias J.
, Rupp, Marco-Christopher
, Scheiderer, Bastian
, Kadantsev, Pavel M.
, Imhoff, Andreas B.
, Berthold, Daniel P.
in
Fixation
/ Hardware
/ Joint and ligament injuries
/ Medicine
/ Medicine & Public Health
/ Orthopedics
/ Patients
/ Risk analysis
/ Risk factors
/ Shoulder
/ Sports Medicine
/ Stabilization
/ Statistical analysis
/ Subgroups
/ Surgery
/ Sutures
2022
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Low rate of substantial loss of reduction immediately after hardware removal following acromioclavicular joint stabilization using a suspensory fixation system
Journal Article
Low rate of substantial loss of reduction immediately after hardware removal following acromioclavicular joint stabilization using a suspensory fixation system
2022
Request Book From Autostore
and Choose the Collection Method
Overview
Purpose
To evaluate immediate loss of reduction in patients undergoing hardware removal after arthroscopically assisted acromioclavicular (AC) joint stabilization using a high-tensile suture tape suspensory fixation system and to identify risk factors associated with immediate loss of reduction.
Materials and methods
Twenty-two consecutive patients with a mean age of 36.4 ± 12.6 years (19–56), who underwent hardware removal 18.2 ± 15.0 months following arthroscopically assisted stabilization surgery using a suspensory fixation system for AC joint injury between 01/2012 and 01/2021 were enrolled in this retrospective monocentric study. The coracoclavicular distance (CCD) as well as the clavicular dislocation/acromial thickness (D/A) ratio were measured on anterior–posterior radiographs prior to hardware removal and immediately postoperatively by two independent raters. Loss of reduction, defined as 10% increase in the CCD, was deemed substantial if the CCD increased 6 mm compared to preoperatively. Constitutional and surgical characteristics were assessed in a subgroup analysis to detect risk factors associated with loss of reduction.
Results
Postoperatively, the CCD significantly increased from 12.6 ± 3.7 mm (4.8–19.0) to 14.5 ± 3.3 mm (8.7–20.6 mm) (
p
< 0.001) while the D/A ratio increased from 0.4 ± 0.3 (− 0.4–0.9) to 0.6 ± 0.3 (1.1–0.1) (
p
= 0.034) compared to preoperatively. In 10 cases (45%), loss of reduction was identified, while a substantial loss of reduction (> 6 mm) was only observed in one patient (4.5%). A shorter time interval between index stabilization surgery and hardware removal significantly corresponded to immediate loss of reduction (11.0 ± 5.6 vs. 30.0 ± 20.8 months;
p
= 0.007), as hardware removal within one year following index stabilization was significantly associated with immediate loss of reduction (
p
= 0.027; relative risk 3.4; odds ratio 11.67).
Conclusions
Substantial loss of reduction after hardware removal of a high-tensile suture tape suspensory fixation system was rare, indicating that the postoperative result of AC stabilization is not categorically at risk when performing this procedure. Even though radiological assessment of the patients showed a statistically significant immediate superior clavicular displacement after this rarely required procedure, with an increased incidence in the first year following stabilization, this may not negatively influence the results of ACJ stabilization in a clinically relevant way.
Level of evidence
IV.