MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Comparison of ASL and DCE MRI for the non-invasive measurement of renal blood flow: quantification and reproducibility
Comparison of ASL and DCE MRI for the non-invasive measurement of renal blood flow: quantification and reproducibility
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Comparison of ASL and DCE MRI for the non-invasive measurement of renal blood flow: quantification and reproducibility
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Comparison of ASL and DCE MRI for the non-invasive measurement of renal blood flow: quantification and reproducibility
Comparison of ASL and DCE MRI for the non-invasive measurement of renal blood flow: quantification and reproducibility

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Comparison of ASL and DCE MRI for the non-invasive measurement of renal blood flow: quantification and reproducibility
Comparison of ASL and DCE MRI for the non-invasive measurement of renal blood flow: quantification and reproducibility
Journal Article

Comparison of ASL and DCE MRI for the non-invasive measurement of renal blood flow: quantification and reproducibility

2014
Request Book From Autostore and Choose the Collection Method
Overview
Objectives To investigate the reproducibility of arterial spin labelling (ASL) and dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) and quantitatively compare these techniques for the measurement of renal blood flow (RBF). Methods Sixteen healthy volunteers were examined on two different occasions. ASL was performed using a multi-TI FAIR labelling scheme with a segmented 3D-GRASE imaging module. DCE MRI was performed using a 3D-FLASH pulse sequence. A Bland-Altman analysis was used to assess repeatability of each technique, and determine the degree of correspondence between the two methods. Results The overall mean cortical renal blood flow (RBF) of the ASL group was 263 ± 41 ml min −1 [100 ml tissue] −1 , and using DCE MRI was 287 ± 70 ml min −1 [100 ml tissue] −1 . The group coefficient of variation (CV g ) was 18 % for ASL and 28 % for DCE-MRI. Repeatability studies showed that ASL was more reproducible than DCE with CV g s of 16 % and 25 % for ASL and DCE respectively. Bland-Altman analysis comparing the two techniques showed a good agreement. Conclusions The repeated measures analysis shows that the ASL technique has better reproducibility than DCE-MRI. Difference analysis shows no significant difference between the RBF values of the two techniques. Key Points • Reliable non-invasive monitoring of renal blood flow is currently clinically unavailable. • Renal arterial spin labelling MRI is robust and repeatable. • Renal dynamic contrast-enhanced MRI is robust and repeatable. • ASL blood flow values are similar to those obtained using DCE-MRI.