Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Comparison of ASL and DCE MRI for the non-invasive measurement of renal blood flow: quantification and reproducibility
by
Clark, Christopher A.
, Hales, Patrick W.
, Gordon, Isky
, Cutajar, Marica
, Thomas, David L.
, Banks, T.
in
Adult
/ Contrast agents
/ Contrast Media
/ Diagnostic Radiology
/ Female
/ Healthy Volunteers
/ Humans
/ Imaging
/ Imaging, Three-Dimensional - methods
/ Imaging, Three-Dimensional - standards
/ Internal Medicine
/ Interventional Radiology
/ Kidney - physiology
/ Kidneys
/ Labeling
/ Magnetic Resonance
/ Magnetic resonance imaging
/ Magnetic Resonance Imaging - methods
/ Magnetic Resonance Imaging - standards
/ Male
/ Medicine
/ Medicine & Public Health
/ Neuroradiology
/ Nuclear medicine
/ Radiation
/ Radiology
/ Renal Artery - physiology
/ Renal Circulation - physiology
/ Reproducibility
/ Reproducibility of Results
/ Spin Labels
/ Ultrasound
/ Young Adult
2014
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Comparison of ASL and DCE MRI for the non-invasive measurement of renal blood flow: quantification and reproducibility
by
Clark, Christopher A.
, Hales, Patrick W.
, Gordon, Isky
, Cutajar, Marica
, Thomas, David L.
, Banks, T.
in
Adult
/ Contrast agents
/ Contrast Media
/ Diagnostic Radiology
/ Female
/ Healthy Volunteers
/ Humans
/ Imaging
/ Imaging, Three-Dimensional - methods
/ Imaging, Three-Dimensional - standards
/ Internal Medicine
/ Interventional Radiology
/ Kidney - physiology
/ Kidneys
/ Labeling
/ Magnetic Resonance
/ Magnetic resonance imaging
/ Magnetic Resonance Imaging - methods
/ Magnetic Resonance Imaging - standards
/ Male
/ Medicine
/ Medicine & Public Health
/ Neuroradiology
/ Nuclear medicine
/ Radiation
/ Radiology
/ Renal Artery - physiology
/ Renal Circulation - physiology
/ Reproducibility
/ Reproducibility of Results
/ Spin Labels
/ Ultrasound
/ Young Adult
2014
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Comparison of ASL and DCE MRI for the non-invasive measurement of renal blood flow: quantification and reproducibility
by
Clark, Christopher A.
, Hales, Patrick W.
, Gordon, Isky
, Cutajar, Marica
, Thomas, David L.
, Banks, T.
in
Adult
/ Contrast agents
/ Contrast Media
/ Diagnostic Radiology
/ Female
/ Healthy Volunteers
/ Humans
/ Imaging
/ Imaging, Three-Dimensional - methods
/ Imaging, Three-Dimensional - standards
/ Internal Medicine
/ Interventional Radiology
/ Kidney - physiology
/ Kidneys
/ Labeling
/ Magnetic Resonance
/ Magnetic resonance imaging
/ Magnetic Resonance Imaging - methods
/ Magnetic Resonance Imaging - standards
/ Male
/ Medicine
/ Medicine & Public Health
/ Neuroradiology
/ Nuclear medicine
/ Radiation
/ Radiology
/ Renal Artery - physiology
/ Renal Circulation - physiology
/ Reproducibility
/ Reproducibility of Results
/ Spin Labels
/ Ultrasound
/ Young Adult
2014
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Comparison of ASL and DCE MRI for the non-invasive measurement of renal blood flow: quantification and reproducibility
Journal Article
Comparison of ASL and DCE MRI for the non-invasive measurement of renal blood flow: quantification and reproducibility
2014
Request Book From Autostore
and Choose the Collection Method
Overview
Objectives
To investigate the reproducibility of arterial spin labelling (ASL) and dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) and quantitatively compare these techniques for the measurement of renal blood flow (RBF).
Methods
Sixteen healthy volunteers were examined on two different occasions. ASL was performed using a multi-TI FAIR labelling scheme with a segmented 3D-GRASE imaging module. DCE MRI was performed using a 3D-FLASH pulse sequence. A Bland-Altman analysis was used to assess repeatability of each technique, and determine the degree of correspondence between the two methods.
Results
The overall mean cortical renal blood flow (RBF) of the ASL group was 263 ± 41 ml min
−1
[100 ml tissue]
−1
, and using DCE MRI was 287 ± 70 ml min
−1
[100 ml tissue]
−1
. The group coefficient of variation (CV
g
) was 18 % for ASL and 28 % for DCE-MRI. Repeatability studies showed that ASL was more reproducible than DCE with CV
g
s of 16 % and 25 % for ASL and DCE respectively. Bland-Altman analysis comparing the two techniques showed a good agreement.
Conclusions
The repeated measures analysis shows that the ASL technique has better reproducibility than DCE-MRI. Difference analysis shows no significant difference between the RBF values of the two techniques.
Key Points
•
Reliable non-invasive monitoring of renal blood flow is currently clinically unavailable.
•
Renal arterial spin labelling MRI is robust and repeatable.
•
Renal dynamic contrast-enhanced MRI is robust and repeatable.
•
ASL blood flow values are similar to those obtained using DCE-MRI.
Publisher
Springer Berlin Heidelberg,Springer Nature B.V
This website uses cookies to ensure you get the best experience on our website.