MbrlCatalogueTitleDetail

Do you wish to reserve the book?
The Verification Process of a POC Blood Gas Analyser—The Nova Stat Profile Primer Plus Analyser
The Verification Process of a POC Blood Gas Analyser—The Nova Stat Profile Primer Plus Analyser
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
The Verification Process of a POC Blood Gas Analyser—The Nova Stat Profile Primer Plus Analyser
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
The Verification Process of a POC Blood Gas Analyser—The Nova Stat Profile Primer Plus Analyser
The Verification Process of a POC Blood Gas Analyser—The Nova Stat Profile Primer Plus Analyser

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
The Verification Process of a POC Blood Gas Analyser—The Nova Stat Profile Primer Plus Analyser
The Verification Process of a POC Blood Gas Analyser—The Nova Stat Profile Primer Plus Analyser
Journal Article

The Verification Process of a POC Blood Gas Analyser—The Nova Stat Profile Primer Plus Analyser

2025
Request Book From Autostore and Choose the Collection Method
Overview
ABSTRACT Background Point‐of‐care testing of blood gases plays a critical role in patient management. The aim of this study was to verify the manufacturer's specifications of the Nova Stat Profile Prime Plus Analyser, along with a comparison study with the GEM Premier 4000 Blood Gas Analyser. Methods Parameters analysed were pH, pCO2, pO2, Na+, Cl−, K+, iCa, lactate, and glucose. Data for the precision and bias study were generated using control samples in a 5 × 5 study design. Linearity was checked using a five‐level Linearity Control Set, while comparison was done between the Nova and GEM analysers using whole blood samples (N = 103). Acceptance was based on the CLIA TEa for all analytes except for lactate, for which the TEa defined by CAP and AAB was used. Results The within‐run and between‐run CVR% precision were all lower than the claimed CVs%, except for pCO2 control level 2 within run (CV% 1.5 [claim CV% 1.1]) and iCa control level 5 between run (CV% 1.42 [claim 1.12]). The observed bias for all parameters was within the calculated lower and upper bias limits. Linearity was verified for all analytes except for Na+. Upon comparison of the Nova and GEM analysers, a correlation coefficient above 0.95 was observed for most parameters. Conclusion The Nova Stat Profile Prime Plus analyser meets the manufacturer's precision and bias claims. Linearity was confirmed for most analytes. There was a good correlation between the Nova and GEM Blood Gas analyser at concentrations within the reference range intervals for all investigated parameters. Point‐of‐care (POC) testing of blood gases plays a critical role in the management of patients both in the emergency department and in a critical care setting. Findings from this study confirm that the Nova Stat Profile Prime Plus analyser meets the manufacturer's precision and bias claims. Linearity was confirmed for pCO2, pO2, K+, Cl‐ and iCa. A good correlation was found between the Nova Stat Profile Prime Plus and GEM Premier Blood Gas analysers at concentrations within the reference range intervals for all the investigated parameters.