MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Time-efficient simultaneous fat and water cardiac cine imaging using spiral magnetic resonance imaging
Time-efficient simultaneous fat and water cardiac cine imaging using spiral magnetic resonance imaging
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Time-efficient simultaneous fat and water cardiac cine imaging using spiral magnetic resonance imaging
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Time-efficient simultaneous fat and water cardiac cine imaging using spiral magnetic resonance imaging
Time-efficient simultaneous fat and water cardiac cine imaging using spiral magnetic resonance imaging

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Time-efficient simultaneous fat and water cardiac cine imaging using spiral magnetic resonance imaging
Time-efficient simultaneous fat and water cardiac cine imaging using spiral magnetic resonance imaging
Journal Article

Time-efficient simultaneous fat and water cardiac cine imaging using spiral magnetic resonance imaging

2025
Request Book From Autostore and Choose the Collection Method
Overview
Cardiac cine imaging is routinely used in patient with suspected or known cardiac dysfunction. Water and fat (W/F) separated cardiovascular magnetic resonance (CMR) will be helpful to distinguish adipose tissue, blood, and myocardium. Inclusion of a multi-echo acquisition in the conventional balanced steady-state free precession (bSSFP) cine sequence can introduce artifacts and reduce temporal resolution. Spiral MRI is known for its signal-to-noise ratio (SNR) efficiency and has the potential to improve temporal efficiency for W/F separated cine imaging. The present work implements a spoiled gradient echo sequence (SPGR) with spiral trajectory to obtain W/F separated cine images simultaneously. Three different sequences were performed for comparison, a Cartesian 2-TE bSSFP sequence, a Cartesian 3-TE bSSFP sequence, and the proposed spiral SPGR sequence. Five volunteers were recruited for the scans on a 1.5T scanner with spatial resolution 1.7×1.7×8.0mm3 over a 400×400mm2 FOV. In addition to qualitative comparisons, a quantitative measurement is performed in terms of the contrast-to-noise ratio (CNR). The proposed method to obtain W/F separated cine images provides better temporal efficiency and fewer artifacts compared to conventional Cartesian bSSFP sequences. The 2-TE bSSFP features the highest artifact level, including susceptibility artifacts and fat/water swaps. The proposed method reduces scan time by approximately 50% with similar spatial and temporal resolution with lower specific absorption rate (SAR). The contrast between the blood pool and myocardium is higher when using the spiral readout (p≤0.05). The results suggest that the presented sequence has potential to facilitate simultaneous imaging for water and fat components in a cine scan while shortening exam time and lowering SAR. [Display omitted]