Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
A split-beam probe-pump-probe scheme for femtosecond time resolved protein X-ray crystallography
by
van Thor, Jasper J.
, Madsen, Anders
in
Ablation
/ CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND SUPERFLUIDITY
/ Crystallography
/ Design parameters
/ Diffraction patterns
/ Femtosecond pulses
/ Free electron lasers
/ Ion beams
/ Noise intensity
/ Proteins
/ Pulse duration
/ Ray tracing
/ Single crystals
/ Structure factor
2015
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
A split-beam probe-pump-probe scheme for femtosecond time resolved protein X-ray crystallography
by
van Thor, Jasper J.
, Madsen, Anders
in
Ablation
/ CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND SUPERFLUIDITY
/ Crystallography
/ Design parameters
/ Diffraction patterns
/ Femtosecond pulses
/ Free electron lasers
/ Ion beams
/ Noise intensity
/ Proteins
/ Pulse duration
/ Ray tracing
/ Single crystals
/ Structure factor
2015
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
A split-beam probe-pump-probe scheme for femtosecond time resolved protein X-ray crystallography
by
van Thor, Jasper J.
, Madsen, Anders
in
Ablation
/ CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND SUPERFLUIDITY
/ Crystallography
/ Design parameters
/ Diffraction patterns
/ Femtosecond pulses
/ Free electron lasers
/ Ion beams
/ Noise intensity
/ Proteins
/ Pulse duration
/ Ray tracing
/ Single crystals
/ Structure factor
2015
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
A split-beam probe-pump-probe scheme for femtosecond time resolved protein X-ray crystallography
Journal Article
A split-beam probe-pump-probe scheme for femtosecond time resolved protein X-ray crystallography
2015
Request Book From Autostore
and Choose the Collection Method
Overview
In order to exploit the femtosecond pulse duration of X-ray Free-Electron Lasers (XFEL) operating in the hard X-ray regime for ultrafast time-resolved protein crystallography experiments, critical parameters that determine the crystallographic signal-to-noise (I/σI) must be addressed. For single-crystal studies under low absorbed dose conditions, it has been shown that the intrinsic pulse intensity stability as well as mode structure and jitter of this structure, significantly affect the crystallographic signal-to-noise. Here, geometrical parameters are theoretically explored for a three-beam scheme: X-ray probe, optical pump, X-ray probe (or “probe-pump-probe”) which will allow experimental determination of the photo-induced structure factor amplitude differences, ΔF, in a ratiometric manner, thereby internally referencing the intensity noise of the XFEL source. In addition to a non-collinear split-beam geometry which separates un-pumped and pumped diffraction patterns on an area detector, applying an additional convergence angle to both beams by focusing leads to integration over mosaic blocks in the case of well-ordered stationary protein crystals. Ray-tracing X-ray diffraction simulations are performed for an example using photoactive yellow protein crystals in order to explore the geometrical design parameters which would be needed. The specifications for an X-ray split and delay instrument that implements both an offset angle and focused beams are discussed, for implementation of a probe-pump-probe scheme at the European XFEL. We discuss possible extension of single crystal studies to serial femtosecond crystallography, particularly in view of the expected X-ray damage and ablation due to the first probe pulse.
Publisher
American Institute of Physics, Inc,American Crystallographic Association/AIP,American Crystallographic Association,AIP Publishing LLC and ACA
MBRLCatalogueRelatedBooks
Related Items
Related Items
This website uses cookies to ensure you get the best experience on our website.