MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Control Mechanisms for Self‐Sealing in Activated Clay‐Rich Faults Through Controlled Hydraulic Injection Experiment
Control Mechanisms for Self‐Sealing in Activated Clay‐Rich Faults Through Controlled Hydraulic Injection Experiment
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Control Mechanisms for Self‐Sealing in Activated Clay‐Rich Faults Through Controlled Hydraulic Injection Experiment
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Control Mechanisms for Self‐Sealing in Activated Clay‐Rich Faults Through Controlled Hydraulic Injection Experiment
Control Mechanisms for Self‐Sealing in Activated Clay‐Rich Faults Through Controlled Hydraulic Injection Experiment

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Control Mechanisms for Self‐Sealing in Activated Clay‐Rich Faults Through Controlled Hydraulic Injection Experiment
Control Mechanisms for Self‐Sealing in Activated Clay‐Rich Faults Through Controlled Hydraulic Injection Experiment
Journal Article

Control Mechanisms for Self‐Sealing in Activated Clay‐Rich Faults Through Controlled Hydraulic Injection Experiment

2025
Request Book From Autostore and Choose the Collection Method
Overview
In a high‐pressure injection fault activation experiment conducted at the Mont Terri underground research laboratory in Switzerland, the transmissivity of the Opalinus Clay fault significantly increased due to opening and shearing. The fluid injection, spanning a few hours, generated a 10 m radius fault activation patch. Subsequent pressure pulse tests conducted bi‐weekly for a year revealed the gradual return of fault transmissivity to its initial state. The study utilized fluid pressure decay analysis, optical fiber monitoring, continuous active source seismic measurements and borehole displacement sensors for measuring fault displacements. The fault zone exhibited a dilation of approximately 1.4 mm, associated with both normal and tangential movements during activation, resulting in a sudden transmissivity increase from 1 × 10−12 to 3.2 × 10−7 m2/s. Early post‐activation, transient compaction and the subsequent slow compaction were observed, transitioning to an extension regime. The pressure pulse tests demonstrated a rapid transmissivity drop by more than two orders of magnitude within the first 10 days, followed by a gradual and less pronounced decrease. Plastic shear and compaction dominated the transmissivity evolution until 70 days after injection ended, followed by a period where additional factors, such as clay mineral swelling, influenced the behavior. Extrapolation suggested a sealing process taking at least 50 years after the initial activation. Plain Language Summary A field‐scale fault activation experiment offers valuable insights into the elasto‐plastic processes governing the sealing of shale faults. The experiment reveals a rapid increase in the fault's transmissivity by approximately five orders of magnitude during activation. Subsequent observations show a gradual transmissivity decrease by about three orders of magnitude post‐activation, with slow long‐term plastic shear and compaction of the fault competing against secondary processes, notably clay mineral swelling. All conceptual models employed to interpret these field data converge on the estimation that the fault's return to its initial low transmissivity state would require a minimum of 50 years. Key Points High‐pressure injection fault activation experiment at the Mont Terri underground research laboratory Continuous transmissivity measurements record self‐sealing inside a clay‐rich fault zone Transmissivity undergoes a phase of domination by slow plastic compaction and shearing during the initial post‐activation period, with mineral swelling exerting its influence over the long term