MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Adversarial denoising of EEG signals: a comparative analysis of standard GAN and WGAN-GP approaches
Adversarial denoising of EEG signals: a comparative analysis of standard GAN and WGAN-GP approaches
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Adversarial denoising of EEG signals: a comparative analysis of standard GAN and WGAN-GP approaches
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Adversarial denoising of EEG signals: a comparative analysis of standard GAN and WGAN-GP approaches
Adversarial denoising of EEG signals: a comparative analysis of standard GAN and WGAN-GP approaches

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Adversarial denoising of EEG signals: a comparative analysis of standard GAN and WGAN-GP approaches
Adversarial denoising of EEG signals: a comparative analysis of standard GAN and WGAN-GP approaches
Journal Article

Adversarial denoising of EEG signals: a comparative analysis of standard GAN and WGAN-GP approaches

2025
Request Book From Autostore and Choose the Collection Method
Overview
Electroencephalography (EEG) signals frequently contain substantial noise and interference, which can obscure clinically and scientifically relevant features. Traditional denoising approaches, such as linear filtering or wavelet thresholding, often struggle with nonlinear or time-varying artifacts. In response, the present study explores a Generative Adversarial Network (GAN) framework to enhance EEG signal quality, focusing on two variants: a conventional GAN model and a Wasserstein GAN with Gradient Penalty (WGAN-GP). Data were obtained from two distinct EEG datasets: a \"healthy\" set of 64-channel recordings collected during various motor/imagery tasks, and an \"unhealthy\" set of 18-channel recordings from individuals with orthopedic impairments. Both datasets underwent comprehensive preprocessing, including band-pass filtering (8-30 Hz), channel standardization, and artifact trimming. The training stage involved adversarial learning, in which a generator sought to reconstruct clean EEG signals while a discriminator (or critic in the case of WGAN-GP) attempted to distinguish between real and generated signals. The model evaluation was conducted using quantitative metrics such as signal-to-noise ratio (SNR), peak signal-to-noise ratio (PSNR), correlation coefficient, mutual information, and dynamic time warping (DTW) distance. Experimental findings indicate that adversarial learning substantially improves EEG signal fidelity across multiple quantitative metrics. Specifically, WGAN-GP achieved an SNR of up to 14.47 dB (compared to 12.37 dB for the standard GAN) and exhibited greater training stability, as evidenced by consistently lower relative root mean squared error (RRMSE) values. In contrast, the conventional GAN model excelled in preserving finer signal details, reflected in a PSNR of 19.28 dB and a correlation coefficient exceeding 0.90 in several recordings. Both adversarial frameworks outperformed classical wavelet-based thresholding and linear filtering methods, demonstrating superior adaptability to nonlinear distortions and dynamic interference patterns in EEG time-series data. By systematically comparing standard GAN and WGAN-GP architectures, this study highlights a practical trade-off between aggressive noise suppression and high-fidelity signal reconstruction. The demonstrated improvements in signal quality underscore the promise of adversarially trained models for applications ranging from basic neuroscience research to real-time brain-computer interfaces (BCIs) in clinical or consumer-grade settings. The results further suggest that GAN-based frameworks can be easily scaled to next-generation wireless networks and complex electrophysiological datasets, offering robust and dynamic solutions to long-standing challenges in EEG denoising.