MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Rationale and design of the randomized, controlled Early Valve Replacement Guided by Biomarkers of Left Ventricular Decompensation in Asymptomatic Patients with Severe Aortic Stenosis (EVOLVED) trial
Rationale and design of the randomized, controlled Early Valve Replacement Guided by Biomarkers of Left Ventricular Decompensation in Asymptomatic Patients with Severe Aortic Stenosis (EVOLVED) trial
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Rationale and design of the randomized, controlled Early Valve Replacement Guided by Biomarkers of Left Ventricular Decompensation in Asymptomatic Patients with Severe Aortic Stenosis (EVOLVED) trial
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Rationale and design of the randomized, controlled Early Valve Replacement Guided by Biomarkers of Left Ventricular Decompensation in Asymptomatic Patients with Severe Aortic Stenosis (EVOLVED) trial
Rationale and design of the randomized, controlled Early Valve Replacement Guided by Biomarkers of Left Ventricular Decompensation in Asymptomatic Patients with Severe Aortic Stenosis (EVOLVED) trial

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Rationale and design of the randomized, controlled Early Valve Replacement Guided by Biomarkers of Left Ventricular Decompensation in Asymptomatic Patients with Severe Aortic Stenosis (EVOLVED) trial
Rationale and design of the randomized, controlled Early Valve Replacement Guided by Biomarkers of Left Ventricular Decompensation in Asymptomatic Patients with Severe Aortic Stenosis (EVOLVED) trial
Journal Article

Rationale and design of the randomized, controlled Early Valve Replacement Guided by Biomarkers of Left Ventricular Decompensation in Asymptomatic Patients with Severe Aortic Stenosis (EVOLVED) trial

2019
Request Book From Autostore and Choose the Collection Method
Overview
The optimal timing of aortic valve replacement in asymptomatic patients with aortic stenosis is uncertain. Replacement fibrosis, as assessed by midwall (nonischemic) late gadolinium enhancement (LGE) on cardiac magnetic resonance (CMR) imaging, is an irreversible marker of left ventricular decompensation in aortic stenosis. Once established, it progresses rapidly and is associated with poor long-term prognosis in a dose-dependent manner. The objective of this multicenter prospective randomized controlled trial is to determine whether early aortic valve replacement in asymptomatic patients with severe aortic stenosis can improve the adverse prognosis associated with midwall LGE. Patients will be screened for likelihood of having LGE with electrocardiography or high-sensitivity troponin I. Those at high risk will proceed to CMR imaging. Approximately 400 patients with midwall LGE will be randomized 1:1 to early valve replacement or routine care. Those who do not exhibit midwall LGE will continue with routine care and be randomized to a study registry or no further follow-up. Follow-up will be annual for approximately 3 years until the number of required outcome events is achieved. The primary endpoint is a composite of all-cause mortality and unplanned aortic stenosis–related hospitalization. The expected event rate is 25.0% in the routine care arm and 13.4% in the early intervention arm over the first 2 years; 88 observed primary outcome events will give 90% power at 5% significance level. Key secondary endpoints include all-cause mortality, sudden cardiac death, stroke, and symptomatic status. The EVOLVED trial is the first multicenter randomized controlled trial to compare early aortic valve replacement to routine care in asymptomatic patients with severe aortic stenosis and midwall LGE.