MbrlCatalogueTitleDetail

Do you wish to reserve the book?
A Single-Step Digestion for the Quantification and Characterization of Trace Particulate Silica Content in Biological Matrices Using Single Particle Inductively Coupled Plasma-Mass Spectrometry
A Single-Step Digestion for the Quantification and Characterization of Trace Particulate Silica Content in Biological Matrices Using Single Particle Inductively Coupled Plasma-Mass Spectrometry
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
A Single-Step Digestion for the Quantification and Characterization of Trace Particulate Silica Content in Biological Matrices Using Single Particle Inductively Coupled Plasma-Mass Spectrometry
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
A Single-Step Digestion for the Quantification and Characterization of Trace Particulate Silica Content in Biological Matrices Using Single Particle Inductively Coupled Plasma-Mass Spectrometry
A Single-Step Digestion for the Quantification and Characterization of Trace Particulate Silica Content in Biological Matrices Using Single Particle Inductively Coupled Plasma-Mass Spectrometry

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
A Single-Step Digestion for the Quantification and Characterization of Trace Particulate Silica Content in Biological Matrices Using Single Particle Inductively Coupled Plasma-Mass Spectrometry
A Single-Step Digestion for the Quantification and Characterization of Trace Particulate Silica Content in Biological Matrices Using Single Particle Inductively Coupled Plasma-Mass Spectrometry
Journal Article

A Single-Step Digestion for the Quantification and Characterization of Trace Particulate Silica Content in Biological Matrices Using Single Particle Inductively Coupled Plasma-Mass Spectrometry

2023
Request Book From Autostore and Choose the Collection Method
Overview
The increased use of amorphous silica nanoparticles (SiNPs) in food products, materials science, cosmetics, and pharmaceuticals has raised questions about potential hazards in the environment and in human health. Although SiNPs are generally thought to be benign, recent studies have demonstrated toxicity in different cell and animal models. Despite their ubiquitous use, SiNPs are rarely analyzed quantitatively. Often, the methods used to analyze silicon and SiNPs are difficult, costly, require the use of dangerous reagents, and are prone to interferences. Additionally, characterization of SiNPs in complex matrices requires extensive sample preparation. To address this, we propose a single-step digestion method for the determination of trace SiNP content in biological matrices. For conventional inductively coupled plasma-mass spectrometry (ICP-MS) analysis, biological samples are often digested with concentrated HNO 3 . We found that with conventional ICP-MS, lower limits of detection (LLOD) of silicon are too high for trace analysis. However, we found that SiNPs are stable at a strong acidic pH; thus, concentrated HNO 3 could be used to digest biological samples leaving SiNPs intact. Then, by analysis with single particle ICP-MS, we found that the smallest SiNP that could be read was 185 nm in size. The concentration for the LLOD was found to be 0.032 ppb with interday variability in sizing and concentration at 2.5% and 6.8% respectively. Utilizing this method, SiNPs were accurately sized and counted in cell pellets and media. Our proposed method can be used to accurately quantify and characterize SiNPs (or agglomerated SiNPs) larger than the derived LLOD in a variety of biological matrices and will assist in determining relationships between exposures of SiNPs and toxicity in humans and the environment.