MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Research on a Precision Calibration Model of a Flexible Strain Sensor Based on a Variable Section Cantilever Beam
Research on a Precision Calibration Model of a Flexible Strain Sensor Based on a Variable Section Cantilever Beam
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Research on a Precision Calibration Model of a Flexible Strain Sensor Based on a Variable Section Cantilever Beam
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Research on a Precision Calibration Model of a Flexible Strain Sensor Based on a Variable Section Cantilever Beam
Research on a Precision Calibration Model of a Flexible Strain Sensor Based on a Variable Section Cantilever Beam

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Research on a Precision Calibration Model of a Flexible Strain Sensor Based on a Variable Section Cantilever Beam
Research on a Precision Calibration Model of a Flexible Strain Sensor Based on a Variable Section Cantilever Beam
Journal Article

Research on a Precision Calibration Model of a Flexible Strain Sensor Based on a Variable Section Cantilever Beam

2023
Request Book From Autostore and Choose the Collection Method
Overview
The flexible strain sensor’s measuring range is usually over 5000 με, while the conventional variable section cantilever calibration model has a measuring range within 1000 με. In order to satisfy the calibration requirements of flexible strain sensors, a new measurement model was proposed to solve the inaccurate calculation problem of the theoretical strain value when the linear model of a variable section cantilever beam was applied to a large range. The nonlinear relationship between deflection and strain was established. The finite element analysis of a variable section cantilever beam with ANSYS shows that the linear model’s relative deviation is as high as 6% at 5000 με, while the relative deviation of the nonlinear model is only 0.2%. The relative expansion uncertainty of the flexible resistance strain sensor is 0.365% (k = 2). Simulation and experimental results show that this method solves the imprecision of the theoretical model effectively and realizes the accurate calibration of a large range of strain sensors. The research results enrich the measurement models and calibration models for flexible strain sensors and contribute to the development of strain metering.