MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Non-enzymatic potentiometric malathion sensing over chitosan-grafted polyaniline hybrid electrode
Non-enzymatic potentiometric malathion sensing over chitosan-grafted polyaniline hybrid electrode
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Non-enzymatic potentiometric malathion sensing over chitosan-grafted polyaniline hybrid electrode
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Non-enzymatic potentiometric malathion sensing over chitosan-grafted polyaniline hybrid electrode
Non-enzymatic potentiometric malathion sensing over chitosan-grafted polyaniline hybrid electrode

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Non-enzymatic potentiometric malathion sensing over chitosan-grafted polyaniline hybrid electrode
Non-enzymatic potentiometric malathion sensing over chitosan-grafted polyaniline hybrid electrode
Journal Article

Non-enzymatic potentiometric malathion sensing over chitosan-grafted polyaniline hybrid electrode

2019
Request Book From Autostore and Choose the Collection Method
Overview
Non-enzymatic electrochemical malathion sensing has been demonstrated over chitosan-grafted polyaniline (CHIT-g-PANI)-based electrode. Structural, morphological, and physical properties of electrode were investigated by Fourier transform infrared (FTIR) spectrometer, X-ray diffraction (XRD), scanning electron microscope (SEM), thermal analysis (TGA), and other relevant ASTM methods. The obtained result suggests the formation of porous hybrid matrix with better free complexing group, electrical conductivity, and thermal stability due to rearrangement of molecular structure and crystallinity. Further, CHIT-g-PANI-based electrode was used for potentiometric sensing of malathion (MLT) in tomato juice by monitoring induced potential due to surface interaction between MLT and CHIT-g-PANI-based electrode. The observed sensing parameters are sensing range 62.5 to 2.0 µM, sensitivity 2.26 mV µM−1 cm−2, limit of detection 3.8 µM, response time 8.0 min, and recovery time 30 s. On the basis observed results a charge transferring, weak surface complexation-based sensing mechanism was proposed in fruits and vegetables in competitive and cost-effective manner.