MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Finite element study of the efficacy of three different loops for bodily protraction of the mandibular molar
Finite element study of the efficacy of three different loops for bodily protraction of the mandibular molar
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Finite element study of the efficacy of three different loops for bodily protraction of the mandibular molar
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Finite element study of the efficacy of three different loops for bodily protraction of the mandibular molar
Finite element study of the efficacy of three different loops for bodily protraction of the mandibular molar

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Finite element study of the efficacy of three different loops for bodily protraction of the mandibular molar
Finite element study of the efficacy of three different loops for bodily protraction of the mandibular molar
Journal Article

Finite element study of the efficacy of three different loops for bodily protraction of the mandibular molar

2025
Request Book From Autostore and Choose the Collection Method
Overview
This study aimed to compare three different loops (T loop, Cherry loop, and Open helical loop) and optimal tip back angle (10°, 15°, 20°) for protraction of mandibular second molar using Finite Element Model (FEM). A CBCT scan of a 20-year-old patient was recorded. It was converted into a CAD file and then into a FEM. A FEM model developed was used to find out the efficacy of the loops and optimal tip-back angles. Displacement of the molar was measured at four reference points: the mesio-buccal cusp, distobuccal cusp, mesial root, and the distal root of the first molar. No significant difference was seen in the displacement for all three loops. At a 10° angle, there was more mesial tipping (5.9°) and molar extrusion. At a 15° angle, there was less mesial tipping (2.9-3°) and no changes in the vertical plane. At a 20° angle, there was bodily movement and intrusion of molars. All three loops are equally effective in the protraction of mandibular molar. A 15° tip back angle was most effective in protracting the mandibular molar as only a negligible amount of mesial tipping of the molar was seen, and there was no extrusion or intrusion of the molar, thus maintaining the occlusal plane. Loop mechanics are preferred over the use of power chains as this helps maintain better control over the molar position during protraction. Loops are very effective at avoiding mesial tipping and extrusion of molars during mesialization to close spaces.